Literature DB >> 29068576

Assessment of the primary stability of root analog zirconia implants designed using cone beam computed tomography software by means of the Periotest® device: An ex vivo study. A preliminary report.

Jacek Matys1, Katarzyna Świder1, Rafał Flieger2, Marzena Dominiak3.   

Abstract

BACKGROUND: The implant primary stability is a fundamental prerequisite for a success of osseointegration process which determines the prosthetic reconstruction time.
OBJECTIVES: The aim of the present study was to assess the quality and precision of modern conical bone computer tomography (CBCT) software in preparing root analog zirconia implants (RAZIs) by measuring its primary stability by means of the Periotest device.
MATERIAL AND METHODS: Thirteen pig jaws with proper erupted first premolar (P1) teeth were used in the study. The CBCT examination was conducted in the area of the P1 tooth in each mandible. The 3-dimensional (3D) view of each tooth was designed from CBCT scan. The created 3D images were used to prepare root analog zirconia implants milled from a medical-grade zirconia block by means of laboratory milling. The RAZIs and titanium implants were placed into an alveolar socket after the tooth had been removed. The primary stability of the teeth before their extraction (G1), RAZIs (G2) and titanium implants (G3) were checked by Periotest devices.
RESULTS: The mean results in PTV were: 15.9, 3.35, 12.7 for G1, G2 and G3 group, respectively. RAZIs during immediate loading achieved a significantly higher primary stability (lower Periotest value) as compared to the teeth and implants.
CONCLUSIONS: The modern CBCT device allows us to design a precise image of an extracted tooth for the purpose of manufacturing a root analog implant. The additional feature of the surgical protocol using RAZI is the possibility of avoiding the augmentation procedure, which reduces the whole cost of the treatment.

Entities:  

Keywords:  Periotest; RAZI; primary stability; root analog zirconia implant

Mesh:

Substances:

Year:  2017        PMID: 29068576     DOI: 10.17219/acem/65069

Source DB:  PubMed          Journal:  Adv Clin Exp Med        ISSN: 1899-5276            Impact factor:   1.727


  9 in total

1.  [Immediate implantation following tooth extraction in fresh maxillary molar socket with poor bone quality].

Authors:  Jing Xu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-01-30

2.  Photobiomodulation by a 635nm Diode Laser on Peri-Implant Bone: Primary and Secondary Stability and Bone Density Analysis-A Randomized Clinical Trial.

Authors:  Jacek Matys; Katarzyna Świder; Kinga Grzech-Leśniak; Marzena Dominiak; Umberto Romeo
Journal:  Biomed Res Int       Date:  2019-04-22       Impact factor: 3.411

3.  Effect of 808 nm Semiconductor Laser on the Stability of Orthodontic Micro-Implants: A Split-Mouth Study.

Authors:  Jacek Matys; Rafał Flieger; Tomasz Gedrange; Krzysztof Janowicz; Bartosz Kempisty; Kinga Grzech-Leśniak; Marzena Dominiak
Journal:  Materials (Basel)       Date:  2020-05-14       Impact factor: 3.623

4.  Biomechanical Effects of a New Macrogeometry Design of Dental Implants: An In Vitro Experimental Analysis.

Authors:  Sergio Alexandre Gehrke; Leticia Pérez-Díaz; Patricia Mazón; Piedad N De Aza
Journal:  J Funct Biomater       Date:  2019-10-25

5.  In Vivo Evaluation of Periodontal Phenotypes Using Cone-Beam Computed Tomography, Intraoral Scanning by Computer-Aided Design, and Prosthetic-Driven Implant Planning Technology.

Authors:  Magdalena Bednarz-Tumidajewicz; Aleksandra Sender-Janeczek; Jacek Zborowski; Tomasz Gedrange; Tomasz Konopka; Agata Prylińska-Czyżewska; Elżbieta Dembowska; Wojciech Bednarz
Journal:  Med Sci Monit       Date:  2020-10-16

6.  The Effects of Insertion Approach on the Stability of Dental Implants.

Authors:  Yuan-Yang Hsu; Heng-Li Huang; Lih-Jyh Fuh; Ming-Tzu Tsai; Jui-Ting Hsu
Journal:  Appl Bionics Biomech       Date:  2022-02-14       Impact factor: 1.781

7.  Optimised Implant Selection Using Digital Volume Tomography (DVT) Osteodensitometry.

Authors:  Manfred Nilius; Jörg Winterhoff
Journal:  Case Rep Dent       Date:  2022-02-14

Review 8.  Efficacy of Various Laser Wavelengths in the Surgical Treatment of Ankyloglossia: A Systematic Review.

Authors:  Iwona Murias; Kinga Grzech-Leśniak; Anna Murias; Katarzyna Walicka-Cupryś; Marzena Dominiak; Janina Golob Deeb; Jacek Matys
Journal:  Life (Basel)       Date:  2022-04-08

9.  Low-Level Laser Therapy with a 635 nm Diode Laser Affects Orthodontic Mini-Implants Stability: A Randomized Clinical Split-Mouth Trial.

Authors:  Rafał Flieger; Tomasz Gedrange; Kinga Grzech-Leśniak; Marzena Dominiak; Jacek Matys
Journal:  J Clin Med       Date:  2019-12-31       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.