Literature DB >> 29062210

Evaluation of outcome of proximal femur locking compression plate (PFLCP) in unstable proximal femur fractures.

Malkesh D Shah1, Chirag S Kapoor1, Rishit J Soni1, Jagdish J Patwa1, Paresh P Golwala1.   

Abstract

INTRODUCTION: Pertrochanteric fractures are most frequent factures of the proximal femur, accounts for nearly 50% of all proximal femur fractures and are most devastating and also a major cause of disability in elderly. The aim and objective of this study was to evaluate the role of proximal femoral locking compression plate in unstable proximal femur fractures. MATERIAL AND
METHOD: A total of 20 cases were included in our study (M:F - 16:4), who suffered proximal femur fracture due to various modalities and all of them were operated using proximal femoral locking compression plate. This proximal femoral fractures included unstable - intertrochanteric with subtrochanteric extension and subtrochanteric with intertrochanteric extensions as well as one case with intertrochanteric, subtrochanteric and neck of femur fracture. Patients were followed up regularly and minimum follow-up period was 12 months. Patients were given physiotherapy and partial weight bearing was started after 6 weeks postoperatively or after union was achieved. The outcome was evaluated as per Harris Hip Score and radiological union. RESULT: Among 20 cases with average age of 55.3 ± 17.9 years, treated with PF-LCP, the average time of union 18.75 ± 3.67 weeks was achieved. We got 10 excellent, 3 good, 3 fair and 4 poor result with average Harris Hip Score of 80.2 ± 28.54 with 65% good to excellent result with average Post-operative Neck Shaft Angle of 124.150 ± 17.880 and with 45% rate of complication which included four cases of superficial infection and two cases of deep infection and late complications like four cases of non-union, deformity - three cases of coxa vara and 2 cases of coxa valga, with patients having more than one complication in them.
CONCLUSION: PF-LCP is not recommended as a definitive implant but can be used as an alternative for the treatment of unstable proximal femoral fractures when there is no option available for other routinely used implants. Despite of its complications, PF-LCP is used where all implants fail.

Entities:  

Keywords:  Anatomical locking plate; Pertrochanteric femur fracture; Proximal femoral locking compression plate (PF-LCP); Unstable proximal femur fracture

Year:  2016        PMID: 29062210      PMCID: PMC5647620          DOI: 10.1016/j.jcot.2016.11.005

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  30 in total

1.  PERTROCHANTERIC FRACTURE OF THE FEMUR.

Authors:  P G Skillern
Journal:  Ann Surg       Date:  1921-02       Impact factor: 12.969

Review 2.  Hip fracture.

Authors:  J D Zuckerman
Journal:  N Engl J Med       Date:  1996-06-06       Impact factor: 91.245

3.  How much do locked screws add to the fixation of "hybrid" plate constructs in osteoporotic bone?

Authors:  Andrew L Freeman; Paul Tornetta; Andrew Schmidt; Joan Bechtold; William Ricci; Mark Fleming
Journal:  J Orthop Trauma       Date:  2010-03       Impact factor: 2.512

4.  Proximal femoral locking compression plate for proximal femoral fractures.

Authors:  Wei Ting Lee; Diarmuid Murphy; Fareed H Y Kagda; Joseph Thambiah
Journal:  J Orthop Surg (Hong Kong)       Date:  2014-12       Impact factor: 1.118

5.  Evaluation of proximal femoral locking plate in unstable extracapsular proximal femoral fractures: Surgical technique & mid term follow up results.

Authors:  Nishikant Kumar; Himanshu Kataria; Chandrashekhar Yadav; Bharath S Gadagoli; Rishi Raj
Journal:  J Clin Orthop Trauma       Date:  2014-09-10

6.  Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation.

Authors:  Henrik Palm; Steffen Jacobsen; Stig Sonne-Holm; Peter Gebuhr
Journal:  J Bone Joint Surg Am       Date:  2007-03       Impact factor: 5.284

7.  Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques.

Authors:  Eric Fulkerson; Kenneth A Egol; Erik N Kubiak; Frank Liporace; Frederick J Kummer; Kenneth J Koval
Journal:  J Trauma       Date:  2006-04

8.  The lateral trochanteric wall: a key element in the reconstruction of unstable pertrochanteric hip fractures.

Authors:  Y Gotfried
Journal:  Clin Orthop Relat Res       Date:  2004-08       Impact factor: 4.176

9.  A new device for the fixation of unstable pertrochanteric fractures of the hip.

Authors:  R J Medoff; K Maes
Journal:  J Bone Joint Surg Am       Date:  1991-09       Impact factor: 5.284

10.  Recent trends in the incidence and lifetime risk of hip fracture in Tottori, Japan.

Authors:  H Hagino; K Furukawa; S Fujiwara; T Okano; H Katagiri; K Yamamoto; R Teshima
Journal:  Osteoporos Int       Date:  2008-07-17       Impact factor: 4.507

View more
  4 in total

1.  Functional and Radiological Outcomes of Unstable Proximal Femur Fractures Fixed With Anatomical Proximal Locking Compression Plate.

Authors:  Vamsee Krishna; Aakaash Venkatesan; Ayush Kumar Singh
Journal:  Cureus       Date:  2022-05-11

2.  Proximal Femoral Plate, Intramedullary Nail Fixation Versus Hip Arthroplasty for Unstable Intertrochanteric Femoral Fracture in the Elderly: A Meta-analysis.

Authors:  Mohamed Shawky El Madboh; Lotfy Mohamed Abd ElKader Yonis; Ibrahim Ali Kabbash; Ahmed Mohamed Samy; Mohamed Abd Elhamed Romeih
Journal:  Indian J Orthop       Date:  2021-06-10       Impact factor: 1.033

3.  Biomechanical Study of Intramedullary Versus Extramedullary Implants for Four Types of Subtrochanteric Femoral Fracture.

Authors:  Jie Wang; Haobo Jia; Xinlong Ma; Jianxiong Ma; Bin Lu; Haohao Bai; Ying Wang
Journal:  Orthop Surg       Date:  2022-06-15       Impact factor: 2.279

4.  Accurate fixation of complicated comminuted femur fracture with customized LCP referencing a life-size 3D-printed model: a case report.

Authors:  He Liu; Baoming Yuan; Tong Yu; Guangkai Ren; Yan Zhang; Yang Wu; Yadong Liu; Chuangang Peng; Dankai Wu
Journal:  Ann Transl Med       Date:  2020-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.