Literature DB >> 29061547

Randomised comparison of JUDkins vs. tiGEr catheter in coronary angiography via the right radial artery: the JUDGE study.

Ioanna Xanthopoulou1, Katerina Stavrou, Periklis Davlouros, Grigorios Tsigkas, Eleni Koufou, Georgios Almpanis, Michalis Koutouzis, Ioannis Tsiafoutis, Angelos Perperis, Athanasios Moulias, Nikolaos Koutsogiannis, George Hahalis.   

Abstract

AIMS: The aim of this study was to compare the performance of the Tiger-II with Judkins 3.5L/4R catheters in coronary angiography (CAG) via the transradial approach (TRA). METHODS AND
RESULTS: Consecutive patients undergoing non-urgent CAG via the right TRA were randomised to either the Tiger-II (Terumo) or Judkins (3.5L/4R; Medtronic) 5 Fr catheters; 320 patients in each group were randomised. Catheter or access site change was required in 57 (17.8%) vs. 68 (21.3%) patients allocated to the Tiger-II and Judkins group, respectively (p=0.3). The study's primary endpoint of contrast volume (ml) used until completion of CAG was lower for Tiger-II vs. Judkins group: 66.8 (54.0-82.0) vs. 73.4 (60.0-94.1), p<0.001. Angiography, fluoroscopy time (min) and severe spasm rate were also significantly lower for Tiger-II vs. Judkins group: 5.52 (4.17-7.32) vs. 6.85 (5.15-9.63), p<0.00, 2.01 (1.32-3.13) vs. 2.24 (1.50-3.50), p=0.01 and 6 (2.8%) vs. 39 (12.2%), p<0.001, respectively. The Tiger-II catheter obtained better opacification grade for the right coronary artery (RCA): 4.0 (4.0-4.0) vs. 4.0 (3.0-4.0), p=0.02, but slightly compromised opacification of the left anterior descending (LAD) and left circumflex (LCX) arteries compared with the Judkins group: 3.75 (3.0-4.0) vs. 4.0 (3.5-4.0), p<0.001, and 3.78 (3.6-4.0) vs. 4.0 (3.6-4.0), p<0.001, respectively.
CONCLUSIONS: The Tiger-II was found superior to the Judkins 3.5L/4R regarding contrast volume use, procedural and fluoroscopy time, spasm rate and RCA imaging, and inferior regarding LAD and LCX imaging.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29061547     DOI: 10.4244/EIJ-D-17-00699

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  5 in total

1.  Can Tiger (TIG) Catheters Be a Solution to the Radial Artery Spasm (RAS) in Coronary Angioplasty? A Case-Based Report of Successful Reperfusion With the Use of 5-French (Fr) TIG Catheter and Literature Review.

Authors:  Zahid Khan; George Besis; Chetan Upadhyaya; Soon Neoh
Journal:  Cureus       Date:  2022-06-25

2.  Predictors of Universal Catheter Failure in Transradial Coronary Angiography.

Authors:  Rebecca Liebenthal; Scott Butler; John Coppola; Binita Shah
Journal:  J Invasive Cardiol       Date:  2019-09-15       Impact factor: 2.022

3.  One Catheter, Two Coronaries. Haven't We Seen This Before?

Authors:  Cesar Rocha Medeiros
Journal:  Arq Bras Cardiol       Date:  2019-11       Impact factor: 2.000

4.  Impact of One-Catheter Strategy with TIG I Catheter on Coronary Catheterization Performance and Economic Costs.

Authors:  Joan Costa-Mateu; Diego Fernández-Rodríguez; Kristian Rivera; Juan Casanova; Patricia Irigaray; Marta Zielonka; Eduardo Pereyra-Acha; Albina Aldomá; Fernando Worner
Journal:  Arq Bras Cardiol       Date:  2019-11       Impact factor: 2.000

5.  Association of genetic variants in lncRNA GAS5/miR-21/mTOR axis with risk and prognosis of coronary artery disease among a Chinese population.

Authors:  Hu Li; Yingxue Liu; Jinyan Huang; Yu Liu; Yufeng Zhu
Journal:  J Clin Lab Anal       Date:  2020-06-17       Impact factor: 2.352

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.