Literature DB >> 29060794

Modified automatic R-peak detection algorithm for patients with epilepsy using a portable electrocardiogram recorder.

J Jeppesen, S Beniczky, A Fuglsang Frederiksen, P Sidenius, P Johansen.   

Abstract

Earlier studies have shown that short term heart rate variability (HRV) analysis of ECG seems promising for detection of epileptic seizures. A precise and accurate automatic R-peak detection algorithm is a necessity in a real-time, continuous measurement of HRV, in a portable ECG device. We used the portable CE marked ePatch® heart monitor to record the ECG of 14 patients, who were enrolled in the videoEEG long term monitoring unit for clinical workup of epilepsy. Recordings of the first 7 patients were used as training set of data for the R-peak detection algorithm and the recordings of the last 7 patients (467.6 recording hours) were used to test the performance of the algorithm. We aimed to modify an existing QRS-detection algorithm to a more precise R-peak detection algorithm to avoid the possible jitter Qand S-peaks can create in the tachogram, which causes error in short-term HRVanalysis. The proposed R-peak detection algorithm showed a high sensitivity (Se = 99.979%) and positive predictive value (P+ = 99.976%), which was comparable with a previously published QRS-detection algorithm for the ePatch® ECG device, when testing the same dataset. The novel R-peak detection algorithm designed to avoid jitter has very high sensitivity and specificity and thus is a suitable tool for a robust, fast, real-time HRV-analysis in patients with epilepsy, creating the possibility for real-time seizure detection for these patients.

Entities:  

Mesh:

Year:  2017        PMID: 29060794     DOI: 10.1109/EMBC.2017.8037753

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

Review 1.  Seizure detection: do current devices work? And when can they be useful?

Authors:  Xiuhe Zhao; Samden D Lhatoo
Journal:  Curr Neurol Neurosci Rep       Date:  2018-05-23       Impact factor: 5.081

2.  Automatic Detection Algorithm for Atrial Fibrillation Based on Atrial Fibrillation and Suspicious Boundary of Sinus Rhythm.

Authors:  Hailing Cui; Ning Dong
Journal:  J Med Syst       Date:  2019-04-26       Impact factor: 4.460

Review 3.  [Mobile seizure monitoring in epilepsy patients].

Authors:  A Schulze-Bonhage; S Böttcher; M Glasstetter; N Epitashvili; E Bruno; M Richardson; K V Laerhoven; M Dümpelmann
Journal:  Nervenarzt       Date:  2019-12       Impact factor: 1.214