Novel blood pressure estimation method using single photoplethysmography feature.

.   

Abstract

Continuous blood pressure (BP) monitoring has a significant meaning to the prevention and early diagnosis of cardiovascular disease. However, existing continuous BP monitoring approaches, especially cuff-less BP monitoring approaches, are all contraptions which complex and huge computation required. For example, for the most sophisticated cuff-less BP monitoring method using pulse transit time (PTT), the simultaneous record of photoplethysmography (PPG) signal and electrocardiography (ECG) are required, and various measurement of characteristic points are needed. These issues hindered widely application of cuff less BP measurement in the wearable devices. In this study, a novel BP estimation method using single PPG signal feature was proposed and its performance in BP estimation was also tested. The results showed that the new approach proposed in this study has a mean error -0.91 ± 3.84 mmHg for SBP estimation and -0.36 ± 3.36 mmHg for DBP estimation respectively. This approach performed better than the traditional PTT based BP estimation, which mean error for SBP estimation was -0.31 ± 4.78 mmHg, and for DBP estimation was -0.18 ± 4.32 mmHg. Further investigation revealed that this new BP estimation approach only required measurement of one characteristic point, reducing much computation when implementing. These results demonstrated that this new approach might be more suitable implemented in the wearable BP monitoring devices.

Entities:  

Mesh:

Year:  2017        PMID: 29060216     DOI: 10.1109/EMBC.2017.8037172

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Small intra-individual variability of the pre-ejection period justifies the use of pulse transit time as approximation of the vascular transit.

Authors:  Minke C Kortekaas; Marit H N van Velzen; Frank Grüne; Sjoerd P Niehof; Robert J Stolker; Frank J P M Huygen
Journal:  PLoS One       Date:  2018-10-10       Impact factor: 3.240

Review 2.  Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring.

Authors:  Manish Hosanee; Gabriel Chan; Kaylie Welykholowa; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-03-07       Impact factor: 4.241

Review 3.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.