Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique.

P M Nabeel1, J Jayaraj, S Mohanasankar.   

Abstract

OBJECTIVE: A novel photoplethysmograph probe employing dual photodiodes excited using a single infrared light source was developed for local pulse wave velocity (PWV) measurement. The potential use of the proposed system in cuffless blood pressure (BP) techniques was demonstrated. APPROACH: Initial validation measurements were performed on a phantom using a reference method. Further, an in vivo study was carried out in 35 volunteers (age  =  28  ±  4.5 years). The carotid local PWV, carotid to finger pulse transit time (PTTR) and pulse arrival time at the carotid artery (PATC) were simultaneously measured. Beat-by-beat variation of the local PWV due to BP changes was studied during post-exercise relaxation. The cuffless BP estimation accuracy of local PWV, PATC, and PTTR was investigated based on inter- and intra-subject models with best-case calibration. MAIN
RESULTS: The accuracy of the proposed system, hardware inter-channel delay (<0.1 ms), repeatability (beat-to-beat variation  =  4.15%-11.38%) and reproducibility of measurement (r  =  0.96) were examined. For the phantom experiment, the measured PWV values did not differ by more than 0.74 m s-1 compared to the reference PWV. Better correlation was observed between brachial BP parameters versus local PWV (r  =  0.74-0.78) compared to PTTR (|r|  =  0.62-0.67) and PATC (|r|  =  0.52-0.68). Cuffless BP estimation using local PWV was better than PTTR and PATC with population-specific models. More accurate estimates of arterial BP levels were achieved using local PWV via subject-specific models (root-mean-square error  ⩽2.61 mmHg). SIGNIFICANCE: A reliable system for cuffless BP measurement and local estimation of arterial wall properties.

Entities:  

Mesh:

Year:  2017        PMID: 29058686     DOI: 10.1088/1361-6579/aa9550

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  17 in total

1.  Cuffless Blood Pressure Monitoring: Promises and Challenges.

Authors:  Jay A Pandit; Enrique Lores; Daniel Batlle
Journal:  Clin J Am Soc Nephrol       Date:  2020-07-17       Impact factor: 8.237

2.  Arterial compliance probe for cuffless evaluation of carotid pulse pressure.

Authors:  Jayaraj Joseph; Nabeel P M; Malay Ilesh Shah; Mohanasankar Sivaprakasam
Journal:  PLoS One       Date:  2018-08-16       Impact factor: 3.240

3.  Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects.

Authors:  Kristen Tgavalekos; Thao Pham; Nishanth Krishnamurthy; Angelo Sassaroli; Sergio Fantini
Journal:  PLoS One       Date:  2019-02-12       Impact factor: 3.240

4.  An Optimization Study of Estimating Blood Pressure Models Based on Pulse Arrival Time for Continuous Monitoring.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Yang Liu; Hongliu Yu
Journal:  J Healthc Eng       Date:  2020-02-10       Impact factor: 2.682

5.  Cuffless blood pressure estimation based on haemodynamic principles: progress towards mobile healthcare.

Authors:  Takehiro Yamakoshi; Peter Rolfe; Ken-Ichi Yamakoshi
Journal:  PeerJ       Date:  2021-05-25       Impact factor: 2.984

6.  Cuffless blood pressure estimation using only a smartphone.

Authors:  Kenta Matsumura; Peter Rolfe; Sogo Toda; Takehiro Yamakoshi
Journal:  Sci Rep       Date:  2018-05-08       Impact factor: 4.379

7.  A Robust Bioimpedance Structure for Smartwatch-Based Blood Pressure Monitoring.

Authors:  Toan Huu Huynh; Roozbeh Jafari; Wan-Young Chung
Journal:  Sensors (Basel)       Date:  2018-06-29       Impact factor: 3.576

Review 8.  Advances in Photopletysmography Signal Analysis for Biomedical Applications.

Authors:  Jermana L Moraes; Matheus X Rocha; Glauber G Vasconcelos; José E Vasconcelos Filho; Victor Hugo C de Albuquerque; Auzuir R Alexandria
Journal:  Sensors (Basel)       Date:  2018-06-09       Impact factor: 3.576

9.  A Revised Point-to-Point Calibration Approach with Adaptive Errors Correction to Weaken Initial Sensitivity of Cuff-Less Blood Pressure Estimation.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Hongliu Yu
Journal:  Sensors (Basel)       Date:  2020-04-13       Impact factor: 3.576

Review 10.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.