Abstract
OBJECTIVE: We conducted a parallel evaluation of the diagnostic accuracy of VIKIA® Rota-Adeno, a rapid diagnostic test (RDT) and Premier™ Rotaclone® an enzyme immunoassay (EIA) using reverse transcription polymerase chain reaction (RT-PCR) as the reference standard. The study was part of a rotavirus surveillance project in Niger.Entities:
Keywords: RT-PCR; Rotaclone; Rotavirus; Sensitivity; Specificity; VIKIA
Mesh:
Substances:
Year: 2017 PMID: 29058617 PMCID: PMC5651622 DOI: 10.1186/s13104-017-2832-1
Source DB: PubMed Journal: BMC Res Notes ISSN: 1756-0500
Performance of Vikia® Rota-Adeno and Premier™ Rotaclone ® compared to RT-PCR on frozen samples
| RT-PCR | Test performance | ||
|---|---|---|---|
| Positive | Negative | Total % sensitivity (95% CI) % specificity (95% CI) | |
| Vikia Rota-Adeno | 80.7 (72.4–87.3) 95.5 (90.4–98.3) | ||
| Positive | 96 | 6 | 102 |
| Negative | 23 | 126 | 149 |
| Premier Rotaclone | 80.7 (72.4–87.3) 100 (97.2–100) | ||
| Visual reading | |||
| Positive | 96 | 0 | 96 |
| Negative | 23 | 131 | 154 |
| Indeterminate | 0 | 1 | 1 |
| Optical density | |||
| Positive | 96 | 0 | 96 |
| Negative | 23 | 132 | 155 |
| Total | 119 | 132 | 251 |
In order to assess possible sample selection bias and freezing/thawing impact on sample rotavirus status, a comparison of the initial VIKIA® Rota-Adeno test in the field for the purposes of surveillance with RT-PCR results on all specimens tested and those selected for the evaluation are shown in Table 2. There was no significant difference between the sensitivity and specificity of the RDT when calculated using all specimens or only those selected for the evaluation, suggesting absence of sample selection bias
Comparison of the initial VIKIA® Rota-Adeno test and RT-PCR results on all specimens tested during the surveillance project and those selected for the evaluation
| RT-PCR | Performance | ||||
|---|---|---|---|---|---|
| Positive | Negative | Total | % sensitivity (95% CI) | % specificity (95% CI) | |
| Initial Vikia Rota-Adeno | |||||
| All specimens | 82.6 (76.5–87.7) | 90.8 (88.1–93.1) | |||
| Positive | 157 | 50 | 207 | ||
| Negative | 33 | 494 | 527 | ||
| Total | 190 | 544 | 734 | ||
| Selected specimens | 84.9 (77.2–90.8) | 92.4 (86.5–96.3) | |||
| Positive | 101 | 10 | 111 | ||
| Negative | 18 | 122 | 140 | ||
| Total | 119 | 132 | 251 | ||