Experimental evaluation of the resolution improvement provided by a silicon PET probe.

K Brzeziński1,2, J F Oliver1, J Gillam1,3, M Rafecas1,4, A Studen5, M Grkovski5,6, H Kagan7, S Smith7, G Llosá1, C Lacasta1, N H Clinthorne8.   

Abstract

A high-resolution PET system, which incorporates a silicon detector probe into a conventional PET scanner, has been proposed to obtain increased image quality in a limited region of interest. Detailed simulation studies have previously shown that the additional probe information improves the spatial resolution of the reconstructed image and increases lesion detectability, with no cost to other image quality measures. The current study expands on the previous work by using a laboratory prototype of the silicon PET-probe system to examine the resolution improvement in an experimental setting. Two different versions of the probe prototype were assessed, both consisting of a back-to-back pair of 1-mm thick silicon pad detectors, one arranged in 32 × 16 arrays of 1.4 mm × 1.4 mm pixels and the other in 40 × 26 arrays of 1.0 mm × 1.0 mm pixels. Each detector was read out by a set of VATAGP7 ASICs and a custom-designed data acquisition board which allowed trigger and data interfacing with the PET scanner, itself consisting of BGO block detectors segmented into 8 × 6 arrays of 6 mm × 12 mm × 30 mm crystals. Limited-angle probe data was acquired from a group of Na-22 point-like sources in order to observe the maximum resolution achievable using the probe system. Data from a Derenzo-like resolution phantom was acquired, then scaled to obtain similar statistical quality as that of previous simulation studies. In this case, images were reconstructed using measurements of the PET ring alone and with the inclusion of the probe data. Images of the Na-22 source demonstrated a resolution of 1.5 mm FWHM in the probe data, the PET ring resolution being approximately 6 mm. Profiles taken through the image of the Derenzo-like phantom showed a clear increase in spatial resolution. Improvements in peak-to-valley ratios of 50% and 38%, in the 4.8 mm and 4.0 mm phantom features respectively, were observed, while previously unresolvable 3.2 mm features were brought to light by the addition of the probe. These results support the possibility of improving the image resolution of a clinical PET scanner using the silicon PET-probe.

Entities:  

Keywords:  Gamma camera; Medical-image reconstruction methods and algorithms; PET PET/CT; SPECT; computer-aided software; coronary CT angiography (CTA)

Year:  2016        PMID: 29057008      PMCID: PMC5648028          DOI: 10.1088/1748-0221/11/09/p09016

Source DB:  PubMed          Journal:  J Instrum        ISSN: 1748-0221            Impact factor:   1.415


  4 in total

1.  Theoretical analysis and simulation study of a high-resolution zoom-in PET system.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2009-08-11       Impact factor: 3.609

2.  Study of a high-resolution PET system using a silicon detector probe.

Authors:  K Brzeziński; J F Oliver; J Gillam; M Rafecas
Journal:  Phys Med Biol       Date:  2014-09-25       Impact factor: 3.609

3.  Silicon as an Unconventional Detector in Positron Emission Tomography.

Authors:  N H Clinthorne; K Brzezinski; E Chesi; E Cochran; M Grkovski; B Grošičar; K Honscheid; S Huh; H Kagan; C Lacasta; V Linhart; M Mikuž; S Smith; V Stankova; A Studen; P Weilhammer; D Zontar
Journal:  Nucl Instrum Methods Phys Res A       Date:  2012-05-14       Impact factor: 1.455

4.  Micro insert: a prototype full-ring PET device for improving the image resolution of a small-animal PET scanner.

Authors:  Heyu Wu; Debashish Pal; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  J Nucl Med       Date:  2008-09-15       Impact factor: 10.057

  4 in total
  1 in total

1.  System resolution versus image uncertainty for positron emission tomography scanners.

Authors:  Andrej Studen; Neal Clinthorne
Journal:  J Med Imaging (Bellingham)       Date:  2022-05-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.