Tricuspid paravalvular leak closure with a paravalvular leak device.

Oleg Polonetsky1, Valery Stelmashok1, Tatiana Sevruk1, Alena Kurlianskaya1, Piotr Pysz2, Grzegorz Smolka2.   

Abstract

Entities:  

Year:  2017        PMID: 29057002      PMCID: PMC5644048          DOI: 10.5114/aic.2017.70202

Source DB:  PubMed          Journal:  Postepy Kardiol Interwencyjnej        ISSN: 1734-9338            Impact factor:   1.426


× No keyword cloud information.
A 69-year-old man, with a permanent pacemaker (PM) and a tricuspid bioprosthesis implanted 6 years ago, was admitted due to gradual exacerbation of heart failure symptoms to NYHA class III. Transthoracic (TTE) and transesophageal (TEE) echocardiography revealed proper function of bioprosthesis leaflets accompanied by the presence of severe paravalvular leak (PVL) with the PM lead crossing its channel. The paravalvular backflow velocity was 3.3 m/s with a calculated right ventricle (RV) to right atrium (RA) gradient of 43 mm Hg and regurgitant volume of 45 ml on TTE. On three-dimensional (3D) TEE the PVL was oval-shaped with dimensions of 7 × 10 mm (Figure 1 A). The interatrial septum (IAS) appeared to be shoved towards the left atrium (LA) with reversed, right-to-left shunt across the patent foramen ovale (PFO). No significant pathology was visualized within the left heart chambers. The Heart Team consulted the patient and a transcatheter closure was scheduled. The procedure was performed in general anesthesia under real time (RT) 3D TEE and fluoroscopy guidance. A rectangular waist-type 8 × 4 mm Paravalvular Leak Device [1] (PLD, Occlutech GmbH) was implanted with a standard vendor delivery system as shown in Figure 1 B. It was chosen as best fitting the PVL anatomy visualized by RT 3D TEE (Figure 1 C). After deployment of the occluder only trivial residual paravalvular flow was present in the area where the PLD bordered the PM lead. Remarkably, within minutes after PLD implantation, the IAS returned to a neutral position between the atria and shunting across the PFO changed direction to left-to-right – Figure 1 D (baseline) and Figure 1 E (post-procedural). No complications occurred and the patient was discharged from hospital on the next day. In 4-week follow-up the patient’s functional capacity improved to NYHA class II. On TTE the RV to RA gradient remained unchanged but the regurgitant volume of residual paravalvular flow was reduced to 12 ml.
Figure 1

Intraprocedural imaging: A, C – RT 3D TEE volume rendering, B – fluoroscopy, D, E – 2D TEE color flow mapping

Intraprocedural imaging: A, C – RT 3D TEE volume rendering, B – fluoroscopy, D, E – 2D TEE color flow mapping
  1 in total

1.  Transcatheter closure of paravalvular leaks using a paravalvular leak device - a prospective Polish registry.

Authors:  Grzegorz Smolka; Piotr Pysz; Michał Kozłowski; Marek Jasiński; Radosław Gocoł; Tomasz Roleder; Agnieszka Kargul; Andrzej Ochała; Wojciech Wojakowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-05-11       Impact factor: 1.426

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.