Literature DB >> 29056395

3D transesophageal echocardiography: A new imaging tool for assessment of mitral regurgitation and for guiding percutaneous edge-to-edge mitral valve repair.

Francesco F Faletra1, Alain Berrebi2, Giovanni Pedrazzini3, Laura Anna Leo3, Vera Lucia Paiocchi3, Giorgio Cautilli3, Gabriele Casso3, Tiziano Cassina3, Tiziano Moccetti3, Joseph F Malouf4.   

Abstract

Real time three dimensional transesophageal echocardiography (3D TEE) is probably the most powerful and convincing imaging method for understanding the complicated multiform morphology and for evaluating geometry, dynamics and function of degenerative and functional mitral valve (MV) regurgitation. Moreover, color Doppler 3D TEE has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. 3D TEE has been shown to be of enormous value in helping surgeons to perform MV repair. In addition, due to its ability to show a "panoramic" view of the "theater" where the procedure takes place, it has become an indispensable companion of 2D TEE during percutaneous edge-to-edge repair. A novel hybrid imaging modality where echocardiography is merged with fluoroscopy, may in the future further improve guidance of this and other complex percutaneous transcatheter interventions.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Mitral clip; Mitral valve regurgitation; Three-dimensional transesophageal echocardiography

Mesh:

Year:  2017        PMID: 29056395     DOI: 10.1016/j.pcad.2017.10.001

Source DB:  PubMed          Journal:  Prog Cardiovasc Dis        ISSN: 0033-0620            Impact factor:   8.194


  4 in total

Review 1.  Innovation in 3D Echocardiographic Imaging.

Authors:  Pei-Ni Jone; Nee Khoo
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-01-19

Review 2.  Real-Time Monitoring and Step-by-Step Guidance for Transapical Mitral Valve Edge-to-Edge Repair Using Transesophageal Echocardiography.

Authors:  Zhenyi Ge; Cuizhen Pan; Wei Li; Daxin Zhou; Wenzhi Pan; Lai Wei; Haiyan Chen; Xianhong Shu; Junbo Ge
Journal:  J Interv Cardiol       Date:  2021-04-21       Impact factor: 2.279

3.  Head to Head Comparison between Different 3-Dimensional Echocardiographic Rendering Tools in the Imaging of Percutaneous Edge-to-Edge Mitral Valve Repair.

Authors:  Gloria Tamborini; Valentina Mantegazza; Anna Garlaschè; Manuela Muratori; Laura Fusini; Sarah Ghulam Ali; Claudia Cefalù; Gianpiero Italiano; Paola Gripari; Anna Maltagliati; Marco Penso; Mauro Pepi
Journal:  J Cardiovasc Dev Dis       Date:  2021-06-24

Review 4.  State-of-the-art intra-procedural imaging for the mitral and tricuspid PASCAL Repair System.

Authors:  Rebecca T Hahn; Susheel K Kodali
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2022-02-22       Impact factor: 6.875

  4 in total