Literature DB >> 29055528

Development of an on-line solid phase extraction ultra-high-performance liquid chromatography technique coupled to tandem mass spectrometry for quantification of bisphenol S and bisphenol S glucuronide: Applicability to toxicokinetic investigations.

Flore Grandin1, Nicole Picard-Hagen2, Véronique Gayrard3, Sylvie Puel4, Catherine Viguié5, Pierre-Louis Toutain6, Laurent Debrauwer7, Marlène Z Lacroix8.   

Abstract

Regulatory measures and public concerns regarding bisphenol A (BPA) have led to its replacement by structural analogues, such as Bisphenol S (BPS), in consumer products. At present, no toxicokinetic investigations have been conducted to assess the factors determining human internal exposure to BPS for subsequent risk assessment. Toxicokinetic studies require reliable analytical methods to measure the plasma concentrations of BPS and its main conjugated metabolite, BPS-glucuronide (BPS-G). An efficient on-line SPE-UPLC-MS/MS method for the simultaneous quantification of BPS and BPS-G in ovine plasma was therefore developed and validated in accordance with the European Medicines Agency guidelines for bioanalytical method validation. This method has a limit of quantification of 3ngmL-1 for BPS and 10ngmL-1 for BPS-G, an analytical capacity of 200 samples per day, and is particularly well suited to toxicokinetic studies. Use of this method in toxicokinetic studies in sheep showed that BPS, like BPA, is efficiently metabolized into its glucuronide form. However, the clearances and distributions of BPS and BPS-G were lower than those of the corresponding unconjugated and glucuroconjugated forms of BPA.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bisphenol S; Bisphenol S glucuronide; Liquid chromatography; Mass spectrometry; Toxicokinetic

Mesh:

Substances:

Year:  2017        PMID: 29055528     DOI: 10.1016/j.chroma.2017.10.020

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Development and Validation of an Analytical Method for Quantitation of Bisphenol S in Rodent Plasma, Amniotic Fluid and Fetuses by UPLC-MS-MS.

Authors:  Melanie A Rehder Silinski; Brenda L Fletcher; Reshan A Fernando; Veronica G Robinson; Suramya Waidyanatha
Journal:  J Anal Toxicol       Date:  2022-03-21       Impact factor: 3.367

2.  Oral Systemic Bioavailability of Bisphenol A and Bisphenol S in Pigs.

Authors:  Véronique Gayrard; Marlène Z Lacroix; Flore C Grandin; Séverine H Collet; Hanna Mila; Catherine Viguié; Clémence A Gély; Blandine Rabozzi; Michèle Bouchard; Roger Léandri; Pierre-Louis Toutain; Nicole Picard-Hagen
Journal:  Environ Health Perspect       Date:  2019-07-17       Impact factor: 9.031

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.