Literature DB >> 29054722

The eyelids and tear film in contact lens discomfort.

Jaya Sowjanya Siddireddy1, Ajay Kumar Vijay2, Jacqueline Tan2, Mark Willcox2.   

Abstract

PURPOSE: To investigate characteristics of the eyelid margins, meibomian glands and the tear film of contact lens wearers, and to determine whether these characteristics were related to symptoms of contact lens discomfort.
METHODS: A cross sectional study was performed on thirty existing daily wear soft contact lens wearers (6 male; 24 female) with median age of 23 years (range 18-41). Eyelid signs and tear film characteristics were evaluated during a single visit and subjects completed the contact lens and dry eye questionnaire (CLDEQ-8) to evaluate ocular discomfort.
RESULTS: Based on the CLDEQ-8 responses, subjects were classified as symptomatic (n = 17) or asymptomatic (n = 13). Grades of foam at meibomian gland orifices (3 ± 1), expressibility (2 ± 1) and quality of secretions (2 ± 1), tear evaporation rate with (112 ± 54 g/m2/h) or without (88 ± 45 g/m2/h) contact lens wear, fluorescein tear breakup time (8 ± 2 seconds) and tear lipid layer thickness (45 ± 17 nm) were significantly associated with symptoms of discomfort in symptomatic lens wearers only (r2 > 0.45; p value < 0.05). Upper lid-wiper epitheliopathy, meibomian gland acini reflectivity and tear meniscus height showed significant correlations with comfort scores in both symptomatic and asymptomatic contact lens wearers (p < 0.05). A greater number of Demodex mites was also observed in the upper eyelid of symptomatic lens wearers (2 ± 1) compared to asymptomatic lens wearers (0 ± 0; p value = 0.042).
CONCLUSIONS: Morphological irregularities of the meibomian glands and alterations to tear film secretions that affect tear evaporative dynamics were associated with symptoms of discomfort amongst the symptomatic lens wearers.
Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Contact lens discomfort; Eyelid margin; Meibomian glands; Tear film

Mesh:

Year:  2017        PMID: 29054722     DOI: 10.1016/j.clae.2017.10.004

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  8 in total

1.  Impact of Improper Approach to Identify Lid Wiper Epitheliopathy (LWE).

Authors:  Christopher W Lievens; Yvonne Norgett; Nancy Briggs; Peter M Allen; Marta Vianya-Estopa
Journal:  Clin Ophthalmol       Date:  2020-10-06

2.  Finite Element Analysis of Cornea and Lid Wiper during Blink, with and without Contact Lens.

Authors:  Vivek Suganthan Ramasubramanian; S Meenatchi Sundaram; Rinu Thomas; S Ve Ramesh; B Raghuvir Pai; Manali Hazarika; Shah Mohammed Abdul Khader; Rakshath G Poojary; H Girish; Vernon Seth Crasto
Journal:  J Ophthalmol       Date:  2022-05-17       Impact factor: 1.974

Review 3.  Investigating the effect of eye cosmetics on the tear film: current insights.

Authors:  Michael Tm Wang; Jennifer P Craig
Journal:  Clin Optom (Auckl)       Date:  2018-04-03

4.  Lotrafilcon B with HydraGlyde moisture matrix or Samfilcon A: Contralateral comparison study for comfort.

Authors:  Nilay Yuksel; Derya Yaman
Journal:  Taiwan J Ophthalmol       Date:  2019 Apr-Jun

5.  Comparison and Evaluation of Prelens Tear Film Stability by Different Noninvasive in vivo Methods.

Authors:  Takashi Itokawa; Takashi Suzuki; Hiroko Iwashita; Yuichi Hori
Journal:  Clin Ophthalmol       Date:  2020-12-21

6.  Orthokeratology Lens Wear for 2 Years in Children Did Not Alter Tear Film Lipid Thickness by Non-Invasive Interferometry.

Authors:  Haozhe Yu; Yifei Yuan; Wenyu Wu; Weizhen Zeng; Louis Tong; Yu Zhang; Yun Feng
Journal:  Front Med (Lausanne)       Date:  2022-02-10

7.  Letter to the Editor re: Dry Eye and Meibomian Glands in Vitiligo

Authors:  Hamidreza Jahanbani-Ardakani; Afshin Moliani; Sadaf Khorrami; Mohammad Reza Khalili; Seyed Hossein Abtahi
Journal:  Turk J Ophthalmol       Date:  2022-04-28

8.  The Effects of Soft Contact Lens Wear on The Tear Film and Meibomian Gland Drop-Out and Visibility.

Authors:  José Vicente García-Marqués; Cristian Talens-Estarelles; Santiago García-Lázaro; Alejandro Cerviño
Journal:  Life (Basel)       Date:  2022-08-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.