Literature DB >> 29054608

A "sweet-spot" for fluid-induced oscillations in the conditioning of stem cell-based engineered heart valve tissues.

Alexander Williams1, Sana Nasim1, Manuel Salinas2, Arash Moshkforoush1, Nikolaos Tsoukias1, Sharan Ramaswamy3.   

Abstract

Fluid-induced shear stresses are involved in the development of cardiovascular tissues. In a tissue engineering framework, this stimulus has also been considered as a mechanical regulator of stem cell differentiation. We recently demonstrated that the fluid-oscillating effect in combination with a physiologically-relevant shear stress magnitude contributes to the formation of stem cell-derived de novo heart valve tissues. However, the range of oscillations necessary to induce favorable gene expression and engineered tissue formation is unknown. In this study, we took a computational approach to establish a range of oscillatory shear stresses that may optimize in vitro valvular tissue growth. Taking a biomimetic approach, three physiologically-relevant flow waveforms from the human: (i) aorta, (ii) pulmonary artery and (iii) superior vena cava were utilized to simulate pulsatile flow conditions within a bioreactor that housed 3 tissue specimens. Results were compared to non-physiological pulsatile flow (NPPF) and cyclic flexure-steady flow (Flex-Flow) conditions. The oscillatory shear index (OSI) was used to quantify the fluid-induced oscillations occurring on the specimen surfaces. The range of mean OSI under the physiological conditions investigated was found to be 0.18 ≤ OSI ≤ 0.23. On the other hand, NPPF and Flex-Flow environments yielded a mean OSI of 0.37 and 0.11 respectively, which were 46% higher and 45% lower than physiological conditions. Moreover, we subsequently conducted OSI-based human bone marrow stem cell (HBMSC) culture experiments which resulted in preferential valvular gene expression and phenotype (significant upregulation of BMP, KLF2A, CD31 and α-SMA using an OSI of 0.23 in comparison to a lower OSI of 0.10 or a higher OSI of 0.38; p < .05). These findings suggest that a distinct range or a "sweet-spot" for physiological OSI exists in the mechanical conditioning of tissue engineered heart valves grown from stem cell sources. We conclude that in vitro heart valve matrix development could be further enhanced by simultaneous exposure of the engineered tissues to physiologically-relevant magnitudes of both fluid-induced oscillations and shear stresses.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Oscillatory shear index (OSI); Oscillatory shear stress (OSS); Physiologically-relevant; Pulsatile flow; Stem cells; Tissue engineered heart valves (TEHVs); Valvular phenotype

Mesh:

Year:  2017        PMID: 29054608     DOI: 10.1016/j.jbiomech.2017.09.035

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Stem Cell Cytoskeletal Responses to Pulsatile Flow in Heart Valve Tissue Engineering Studies.

Authors:  Glenda Castellanos; Sana Nasim; Denise M Almora; Sasmita Rath; Sharan Ramaswamy
Journal:  Front Cardiovasc Med       Date:  2018-06-05

Review 2.  Experimental and computational models for tissue-engineered heart valves: a narrative review.

Authors:  Ge Yan; Yuqi Liu; Minghui Xie; Jiawei Shi; Weihua Qiao; Nianguo Dong
Journal:  Biomater Transl       Date:  2021-12-28

3.  Valve Endothelial Cell Exposure to High Levels of Flow Oscillations Exacerbates Valve Interstitial Cell Calcification.

Authors:  Chia-Pei Denise Hsu; Alexandra Tchir; Asad Mirza; Daniel Chaparro; Raul E Herrera; Joshua D Hutcheson; Sharan Ramaswamy
Journal:  Bioengineering (Basel)       Date:  2022-08-16

Review 4.  Oscillatory fluid-induced mechanobiology in heart valves with parallels to the vasculature.

Authors:  Chia-Pei Denise Hsu; Joshua D Hutcheson; Sharan Ramaswamy
Journal:  Vasc Biol       Date:  2020-02-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.