Surgical strategy for aortic arch reconstruction after the Norwood procedure based on numerical flow analysis.

Shohei Miyazaki1, Kagami Miyaji1, Keiichi Itatani2, Norihiko Oka1, Shinji Goto3, Masanori Nakamura4, Tadashi Kitamura1, Tetsuya Horai1, Koichi Sughimoto1, Yuki Nakamura1, Naoki Yoshimura5.   

Abstract

OBJECTIVES: Inefficient aortic flow after the Norwood procedure is known to lead to the deterioration of ventricular function due to an increased cardiac workload. To prevent the progression of aortic arch obstruction, arch reconstruction concomitant with second-stage surgery is recommended. The aim of this study was to determine the indications for reconstruction based on numerical simulation and to reveal the morphology that affects the haemodynamic parameters.
METHODS: Fifteen patients who underwent the Norwood procedure or arch repair and Damus-Kaye-Stansel anastomosis were enrolled. The pressure gradient in aortic arch was 1.6 ± 3.9 mmHg (ranged from 0 to 12 mmHg) on catheter examination. Six patients who had prominent turbulent flow accompanied with a large flow energy loss index greater than 40 mW/m2 and high wall shear stress greater than 100 Pa underwent arch reconstruction.
RESULTS: After arch reconstruction, the energy loss index significantly decreased from 88.5 ± 50.0 mW/m2 to 23.1 ± 10.4 mW/m2 (P = 0.026) and wall shear stress significantly decreased from 194.5 ± 87.4 Pa to 60.3 ± 40.5 Pa (P = 0.0062). There were 3 late deaths due to heart failure caused by progressive atrioventricular valve regurgitation during the follow-up period (60 months). The systemic ventricular function was preserved in the remaining patients without any pressure gradients in the arch.
CONCLUSIONS: Determining the surgical strategy for arch reconstruction based on numerical flow analysis may effectively reduce the ventricular load even if no stenosis or pressure gradients are observed on catheter examination or echocardiography.
© The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 29049796     DOI: 10.1093/icvts/ivx332

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  3 in total

1.  Hemodynamic Analysis of a Microanastomosis Using Computational Fluid Dynamics.

Authors:  Shunjiro Yagi; Takafumi Sasaki; Takahiro Fukuhara; Kaori Fujii; Maki Morita; Yoshiko Suyama; Kohei Fukuoka; Teruyasu Nishino; Ichiro Hisatome
Journal:  Yonago Acta Med       Date:  2020-10-29       Impact factor: 1.641

2.  Hemodynamic Analysis of a Three-Point Suture During Tapering Technique for Microanastomosis Using Computational Fluid Dynamics.

Authors:  Shunjiro Yagi; Takafumi Sasaki; Takahiro Fukuhara; Kaori Fujii; Maki Morita; Kohei Fukuoka; Kento Ikuta; Ryunosuke Umeda; Haruka Kanayama; Yoshiko Suyama
Journal:  J Craniofac Surg       Date:  2021 Nov-Dec 01       Impact factor: 1.172

3.  Outcomes of Norwood procedure with hypoplastic left heart syndrome: Our 12-year single-center experience.

Authors:  Fatih Özdemir; Oktay Korun; Mehmet Dedemoğlu; Murat Çiçek; Mehmet Biçer; Okan Yurdakök; Hüsnü Fırat Altın; Emine Hekim Yılmaz; Nurgül Yurtseven; Numan Ali Aydemir; Ahmet Şaşmazel
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2022-01-28       Impact factor: 0.332

  3 in total