| Literature DB >> 29047783 |
Hongda Tai, Zibo Zhuang, Dongsong Sun.
Abstract
Accurate measurements of visibility are of great importance in many fields. This paper reports a multipoint visibility measurement (MVM) method to measure and calculate the atmospheric transmittance, extinction coefficient, and meteorological optical range (MOR). The relative errors of atmospheric transmittance and MOR measured by the MVM method and traditional transmissometer method are analyzed and compared. Experiments were conducted indoors, and the data were simultaneously processed. The results revealed that the MVM can effectively improve the accuracy under different visibility conditions. The greatest improvement of accuracy was 27%. The MVM can be used to calibrate and evaluate visibility meters.Year: 2017 PMID: 29047783 DOI: 10.1364/AO.56.007952
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980