| Literature DB >> 29043190 |
Thuong T Nguyen1, Barbara McKinney2, Antoine Pierson3, Khue N Luong4, Quynh T Hoang5, Sandeep Meharwal6, Humberto M Carvalho7, Cuong Q Nguyen8, Kim T Nguyen9, Kyle B Bond5.
Abstract
BACKGROUND: The Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist is used worldwide to drive quality improvement in laboratories in developing countries and to assess the effectiveness of interventions such as the Strengthening Laboratory Management Toward Accreditation (SLMTA) programme. However, the paper-based format of the checklist makes administration cumbersome and limits timely analysis and communication of results. DEVELOPMENT OF E-TOOL: In early 2012, the SLMTA team in Vietnam developed an electronic SLIPTA checklist tool. The e-Tool was pilot tested in Vietnam in mid-2012 and revised. It was used during SLMTA implementation in Vietnam and Cambodia in 2012 and 2013 and further revised based on auditors' feedback about usability. OUTCOMES: The SLIPTA e-Tool enabled rapid turn-around of audit results, reduced workload and language barriers and facilitated analysis of national results. Benefits of the e-Tool will be magnified with in-country scale-up of laboratory quality improvement efforts and potential expansion to other countries.Entities:
Year: 2014 PMID: 29043190 PMCID: PMC5637789 DOI: 10.4102/ajlm.v3i2.219
Source DB: PubMed Journal: Afr J Lab Med ISSN: 2225-2002
Challenges of the paper-based SLIPTA checklist, and solutions provided by the SLIPTA e-Tool.
| Area for improvement | Challenges associated with paper-based checklist | e-Tool solutions |
|---|---|---|
| Audit process | Scoring errors when results are calculated manually | Automatically calculates scores as data are entered, with built-in data limit checks |
| Length of time required for recording and entering data | On-site data entry into e-Tool reduces time to perform audit and eliminates the need to transfer data from hard copies into electronic format | |
| Communication | Delays in reporting of results; manual calculations add at least one additional day to the audit process | Results are calculated on-site and presented immediately after audit |
| Hospital administration is often not available at the follow-up visit; delays reduce motivation for improvement | Results are available on-site in real time while hospital administrators and laboratorians are present and highly motivated to make further improvements | |
| No standard graphical representation of results leading to a lack of clear messaging and possibility of misinterpretation | A one-page report with graphical display of the results is created automatically and presented by the team at the conclusion of the audit | |
| Paper-based tool in English only | Multi-language e-Tool reduces language barriers to improve communication and accessibility | |
| Data management | Data not available electronically for accessibility and data analysis | Data are available for extraction and statistical analysis |
| Difficulty combining results from repeated audits | e-Tool combines and compares results across audits and displays data | |
| Difficult and time-consuming to combine results from multiple laboratories to create country-level graphics and summaries | e-Tool automatically combines data from multiple laboratories into one graphical representation, with summary statistics, for country-wide program management | |
| Scanning and storing paper copies of results | Electronic storage is convenient for multiple audits and sharing of information with stakeholders |
SLIPTA, Stepwise Laboratory Quality Improvement Process Towards Accreditation.
FIGURE 1Example of e-Tool data output for baseline (row 1) and exit audit (other rows) for Section 1 (Documents and Records) compiled from 12 laboratories in Vietnam, 2013.
FIGURE 2Visualised results for 12 laboratories in Vietnam using the SLIPTA e-Tool. (2a) Spider plot of combined baseline (May 2012) and exit (June to July 2013) audit median data for all 12 laboratory sites. (2b) Computer screen shot of baseline audit data for Section 1 (Documents and Records) of the SLIPTA checklist with bar-chart results. Colours indicate results that are acceptable (green), unacceptable (red) or partially compliant (yellow). (2c) Computer screen shot of exit audit data for Section 1 (Documents and Records) of the SLIPTA checklist with bar-chart results.