Literature DB >> 29039944

3D-Printed Microflow Injection Analysis Platform for Online Magnetic Nanoparticle Sorptive Extraction of Antimicrobials in Biological Specimens as a Front End to Liquid Chromatographic Assays.

Han Wang1, David J Cocovi-Solberg2, Bin Hu1, Manuel Miró2.   

Abstract

In this work, the concept of 3D-printed microflow injection (3D-μFI) embodying a dedicated multifunctional 3D-printed stator onto a rotary microvalve along with a mesofluidic sample preparation platform is proposed for the first time. A transparent 3D-printed stereolithographic mesofluidic chip device accommodating polyaniline (PANI) decorated magnetic nanoparticles (32.5 ± 3.8 mg) is harnessed to in-line sorptive microextraction as a front end to liquid chromatography with peak focusing. As a proof-of-concept application, the 3D-μFI assembly was resorted to matrix cleanup and automatic programmable-flow determination of organic emerging contaminants (4-hydroxybenzoate analogues and triclosan as antimicrobial model analytes) in human saliva and urine samples. By using a sample volume of 1.0 mL with a loading flow rate of 200 μL min-1, an eluent volume of 120 μL at 80 μL min-1, and online HPLC injection of 300 μL of the mixture of eluate and Milli-Q water (in a 1:2 ratio) to prevent band broadening effects of the most polar analytes, the limits of detection (3σ criterion) ranged from 1.1 to 4.5 ng mL-1 for methylparaben (MP), ethylparaben (EP), propylparaben (PrP), phenylparaben (PhP), butylparaben (BP), and triclosan (TCS). Enhancement factors of 16-25 were obtained for the target analytes. Spike recoveries ranged from 84 to 117% for both saliva and urine samples. The online 3D-μFI hyphenated method is synchronized with the chromatographic separation and features a chip lifetime of more than 20 injections with minimal losses of moderately nonpolar compounds on the walls of the mesofluidic device.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29039944     DOI: 10.1021/acs.analchem.7b03767

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Electrode modified with graphene quantum dots supported in chitosan for electrochemical methods and non-linear deconvolution of spectra for spectrometric methods: approaches for simultaneous determination of triclosan and methylparaben.

Authors:  Edson Roberto Santana; Almir Spinelli
Journal:  Mikrochim Acta       Date:  2020-03-28       Impact factor: 5.833

2.  3D-printed, TiO2 NP-incorporated minicolumn coupled with ICP-MS for speciation of inorganic arsenic and selenium in high-salt-content samples.

Authors:  Cheng-Kuan Su; Wei-Cheng Chen
Journal:  Mikrochim Acta       Date:  2018-04-25       Impact factor: 5.833

Review 3.  Low-cost and open-source strategies for chemical separations.

Authors:  Joshua J Davis; Samuel W Foster; James P Grinias
Journal:  J Chromatogr A       Date:  2020-12-24       Impact factor: 4.759

Review 4.  Use of Nanomaterial-Based (Micro)Extraction Techniques for the Determination of Cosmetic-Related Compounds.

Authors:  José Grau; Juan L Benedé; Alberto Chisvert
Journal:  Molecules       Date:  2020-06-02       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.