Literature DB >> 29037843

Spatio-Temporal Flow and Wall Shear Stress Mapping Based on Incoherent Ensemble-Correlation of Ultrafast Contrast Enhanced Ultrasound Images.

Chee Hau Leow1, Meng-Xing Tang2.   

Abstract

In this study, a technique for high-frame-rate ultrasound imaging velocimetry (UIV) is extended first to provide more robust quantitative flow velocity mapping using ensemble correlation of images without coherent compounding, and second to generate spatio-temporal wall shear stress (WSS) distribution. A simulation model, which couples the ultrasound simulator with analytical flow solution, was implemented to evaluate its accuracy. It is shown that the proposed approach can reduce errors in velocity estimation by up to 10-fold in comparison with the coherent correlation approach. Mean errors (ME) of 3.2% and 8.6% were estimated under a steady flow condition, while 3.0% and 10.6% were found under a pulsatile condition for the velocity and wall shear rate (WSR) measurement, respectively. Appropriate filter parameters were selected to constrain the velocity profiles before WSR estimations and the effects of incorrect wall tracking were quantified under a controlled environment. Although accurate wall tracking is found to be critical in WSR measurement (as a 200 µm deviation from the wall may yield up to a 60% error), this can be mitigated by HFR imaging (of up to 10 kHz) with contrast agents, which allow for improved differentiation of the wall-fluid boundaries. In vitro investigations on two carotid bifurcation phantoms, normal and diseased, were conducted, and their relative differences in terms of the flow patterns and WSR distribution were demonstrated. It is shown that high-frame-rate UIV technique can be a non-invasive tool to measure quantitatively the spatio-temporal velocity and WSS distribution.
Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

Keywords:  Contrast enhanced ultrasound; Flow measurement; Image tracking; Microbubble contrast agents; Motion effect; Ultrafast ultrasound imaging; Wall shear rate

Mesh:

Substances:

Year:  2017        PMID: 29037843     DOI: 10.1016/j.ultrasmedbio.2017.08.930

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  High-frame-rate contrast-enhanced ultrasound particle image velocimetry in patients with a stented superficial femoral artery: a feasibility study.

Authors:  Majorie van Helvert; Stefan Engelhard; Jason Voorneveld; Marije van der Vee; Johan G Bosch; Michel Versluis; Erik Groot Jebbink; Michel M P J Reijnen
Journal:  Eur Radiol Exp       Date:  2022-07-06

2.  Pulse Wave Imaging Coupled With Vector Flow Mapping: A Phantom, Simulation, and In Vivo Study.

Authors:  Grigorios Marios Karageorgos; Iason-Zacharias Apostolakis; Pierre Nauleau; Vittorio Gatti; Rachel Weber; Paul Kemper; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-06-29       Impact factor: 3.267

3.  3-D Flow Reconstruction Using Divergence-Free Interpolation of Multiple 2-D Contrast-Enhanced Ultrasound Particle Imaging Velocimetry Measurements.

Authors:  Xinhuan Zhou; Virginie Papadopoulou; Chee Hau Leow; Peter Vincent; Meng-Xing Tang
Journal:  Ultrasound Med Biol       Date:  2019-01-04       Impact factor: 2.998

4.  Determining Haemodynamic Wall Shear Stress in the Rabbit Aorta In Vivo Using Contrast-Enhanced Ultrasound Image Velocimetry.

Authors:  K Riemer; E M Rowland; C H Leow; M X Tang; P D Weinberg
Journal:  Ann Biomed Eng       Date:  2020-03-04       Impact factor: 3.934

5.  Measurement of Flow Volume in the Presence of Reverse Flow with Ultrasound Speckle Decorrelation.

Authors:  Xiaowei Zhou; Xinhuan Zhou; Chee Hau Leow; Meng-Xing Tang
Journal:  Ultrasound Med Biol       Date:  2019-08-01       Impact factor: 2.998

6.  In vitro performance of echoPIV for assessment of laminar flow profiles in a carotid artery stent.

Authors:  Astrid M Hoving; Jason Voorneveld; Julia Mikhal; Johan G Bosch; Erik Groot Jebbink; Cornelis H Slump
Journal:  J Med Imaging (Bellingham)       Date:  2021-01-13

7.  Innovative Multiparametric Characterization of Carotid Plaque Vulnerability by Ultrasound.

Authors:  Guillaume Goudot; Lina Khider; Olivier Pedreira; Jonathan Poree; Pierre Julia; Jean-Marc Alsac; Kisaki Amemiya; Patrick Bruneval; Emmanuel Messas; Mathieu Pernot; Tristan Mirault
Journal:  Front Physiol       Date:  2020-03-03       Impact factor: 4.566

8.  Contrast Agent-Free Assessment of Blood Flow and Wall Shear Stress in the Rabbit Aorta using Ultrasound Image Velocimetry.

Authors:  Kai Riemer; Ethan M Rowland; Jacob Broughton-Venner; Chee Hau Leow; Mengxing Tang; P D Weinberg
Journal:  Ultrasound Med Biol       Date:  2021-12-05       Impact factor: 2.998

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.