Literature DB >> 29037693

Conducting polymer modified screen-printed carbon electrode coupled with magnetic solid phase microextraction for determination of caffeine.

Hayati Filik1, Asiye Aslıhan Avan2.   

Abstract

In the current study, we introduce magnetic solid phase microextraction coupled with electrochemical detection of caffeine. A commercially available disposable screen-printed carbon electrodes modified with poly Alizarin Red S are employed as electrochemical sensors in the detection stage. However, the suitability of magnetic solid phase microextraction for electroanalytical methods such as square wave voltammetry has not been declared. With our optimised conditions in hand, the system response was linearly proportional to the concentration of caffeine in the range of 0.5-20µM with a correlation coefficient of about 0.9987. The detection limit of the sensing system was found to be 0.05µM (a signal-to-noise ratio of 3). At the end of the study, the suitability of this new procedure for the analysis of energy drink, soft drink, and chocolate milk samples was demonstrated.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Analysis; Caffeine; Magnetic solid phase microextraction; Preconcentration; Screen-printed carbon electrode; Voltammetry

Mesh:

Substances:

Year:  2017        PMID: 29037693     DOI: 10.1016/j.foodchem.2017.09.068

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  3 in total

Review 1.  A Comprehensive Review: Development of Electrochemical Biosensors for Detection of Cyanotoxins in Freshwater.

Authors:  Vasileia Vogiazi; Armah de la Cruz; Siddharth Mishra; Vesselin Shanov; William R Heineman; Dionysios D Dionysiou
Journal:  ACS Sens       Date:  2019-05-14       Impact factor: 7.711

2.  New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment.

Authors:  Hisham S M Abd-Rabboh; Abdel El-Galil E Amr; Abdulrahman A Almehizia; Ahmed M Naglah; Ayman H Kamel
Journal:  Polymers (Basel)       Date:  2022-05-10       Impact factor: 4.967

3.  Magnetic dispersive solid-phase extraction using a zeolite-based composite for direct electrochemical determination of lead(II) in urine using screen-printed electrodes.

Authors:  Elena Fernández; Lorena Vidal; Joaquín Silvestre-Albero; Antonio Canals
Journal:  Mikrochim Acta       Date:  2020-01-02       Impact factor: 5.833

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.