The Bigger the Hand, the Bigger the Difference? Implications for Testing Strength With 2 Popular Handgrip Dynamometers.

Takashi Abe, Jeremy P Loenneke, Robert S Thiebaud, Mark Loftin.   

Abstract

CONTEXT: Studies developed the frail elderly handgrip strength (HGS) diagnostic criteria using multiple types of handgrip dynamometers. If different handgrip dynamometers report different values, then this would have the potential to misclassify people into the wrong diagnostic category.
OBJECTIVE: To examine the characteristics of HGS measured by 2 standard handgrip dynamometers and to investigate the influence of hand size on HGS.
SETTING: University research laboratory. PARTICIPANTS: A total of 87 young and middle-aged adults between the ages of 20 and 60 years participated in this study. MAIN OUTCOME MEASURES: Standard methods of HGS measurements were used for hydraulic and Smedley spring-type dynamometers, although the participants were instructed to maintain an upright standing position in both tests.
RESULTS: Test-retest reliability of hydraulic and Smedley dynamometers provided comparable results to that observed with previous studies. However, the difference in HGS between the 2 dynamometers (Hydraulic-Smedley difference) was positively associated (r = .670, P < .001) with the mean of the 2 dynamometers. The participants who had relatively low HGS (at least <35 kg) produced similar HGS values when the 2 dynamometers were compared, whereas persons who had relatively higher HGS (at least >45 kg) produced greater strength values with the hydraulic compared with the Smedley. The hand and palm lengths were weakly correlated (r = .349 and r = .358, respectively, both Ps < .001) with the difference in HGS between the 2 dynamometers.
CONCLUSIONS: Test-retest reliability of hydraulic and Smedley dynamometers provides comparable results to previous studies. However, the difference in HGS between the 2 dynamometers was positively associated with the mean of the 2 dynamometers. This Hydraulic-Smedley difference would not affect persons who have relatively low HGS (at least <35 kg), while when HGS is relatively high, the comparison between dynamometers should be done with caution.

Entities:  

Keywords:  grip span; hand and palm length; hand strength; reliability; sarcopenia

Mesh:

Year:  2018        PMID: 29035647     DOI: 10.1123/jsr.2017-0189

Source DB:  PubMed          Journal:  J Sport Rehabil        ISSN: 1056-6716            Impact factor:   1.931


  2 in total

1.  Assessing Additional Characteristics of Muscle Function With Digital Handgrip Dynamometry and Accelerometry: Framework for a Novel Handgrip Strength Protocol.

Authors:  Ryan McGrath; Grant R Tomkinson; Brian C Clark; Peggy M Cawthon; Matteo Cesari; Soham Al Snih; Donald A Jurivich; Kyle J Hackney
Journal:  J Am Med Dir Assoc       Date:  2021-06-21       Impact factor: 4.669

2.  Differences in toe flexor strength and foot morphology between wheelchair dependent and ambulant older people in long-term care: a cross-sectional study.

Authors:  Mieko Yokozuka; Sei Sato
Journal:  J Foot Ankle Res       Date:  2021-03-12       Impact factor: 2.303

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.