Clinical Impact of the Microembolic Signal Burden During Catheter Ablation for Atrial Fibrillation: Just a Lot of Noise?

Christian von Bary1,2, Thomas Deneke3, Thomas Arentz4, Anja Schade3, Heiko Lehrmann4, Susanne Schwab-Malek5, Sabine Fredersdorf2, Dobri Baldaranov5, Lars Maier2, Felix Schlachetzki5.   

Abstract

OBJECTIVES: Microembolic signal detection by transcranial Doppler ultrasonography may be considered a surrogate for cerebral events during invasive cardiac procedures. However, the impact of the microembolic signal count during pulmonary vein isolation on the clinical outcome is not well evaluated. We investigated the effect of the microembolic signal count on the occurrence of new silent cerebral embolism measured by diffusion-weighted imaging (DWI)-magnetic resonance imaging (MRI), changes in neuropsychological testing, and the occurrence of clinical events during long-term follow-up after pulmonary vein isolation.
METHODS: Pulmonary vein isolation was performed in 41 patients. The total microembolic signal burden (classified into "solid," "gaseous," and "equivocal") and sustained thromboembolic showers of greater than 30 seconds were recorded. Diffusion-weighted imaging-MRI and neuropsychological testing were performed before and after pulmonary vein isolation to assess for silent cerebral embolism and neuropsychological sequelae. Long-term follow-up was performed by telephone to assess for stroke/transient ischemic attack.
RESULTS: A total of 68,729 microembolic signals (14,893 solid, 11,909 gaseous, and 41,927 equivocal) with an average of 1676 signals per patient and 42 thromboembolic showers were recorded. No correlation between the microembolic signal/thromboembolic shower count and the occurrence of new DWI lesions or neuropsychological capability was found. After a mean follow-up ± SD of 49 ± 4 months, 1 patient had an overt transient ischemic event, which was not associated with a high microembolic signal count.
CONCLUSIONS: In this multicenter study, we found no impact of the intraprocedural microembolic symbol/thromboembolic shower count on the occurrence of new DWI lesions, neuropsychological capability, or overt neurologic deficits after pulmonary vein isolation. Thus, not only the microembolic signal count but also procedural/individual factors may contribute to commensurable clinical damage, which may challenge this method as a valid biomarker during pulmonary vein isolation.
© 2017 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  ablation; atrial fibrillation; intraoperative; invasive techniques; magnetic resonance imaging; neuropsychology; transcranial Doppler (adult)

Mesh:

Year:  2017        PMID: 29034496     DOI: 10.1002/jum.14447

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

Review 1.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

2.  Microembolic signal detection by transcranial Doppler: Old method with a new indication.

Authors:  Sombat Muengtaweepongsa; Charturong Tantibundhit
Journal:  World J Methodol       Date:  2018-11-29

3.  Simple periprocedural precautions to reduce Doppler microembolic signals during AF ablation.

Authors:  Marian Christoph; David Poitz; Silvio Quick; Carsten Wunderlich; Christian Pfluecke; Mathias Forkmann; Yan Huo; Thomas Gaspar; Steffen Schoen; Karim Ibrahim
Journal:  J Interv Card Electrophysiol       Date:  2021-05-31       Impact factor: 1.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.