Literature DB >> 29033154

The Use of Porous Tantalum Augments for the Reconstruction of Acetabular Defect in Primary Total Hip Arthroplasty.

Ting-Xian Ling1, Jin-Long Li1, Kai Zhou1, Qiang Xiao1, Fu-Xing Pei1, Zong-Ke Zhou1.   

Abstract

BACKGROUND: Given the lack of studies of acetabular defect reconstruction in primary total hip arthroplasty (THA) using tantalum augments, this study aims to evaluate clinical and radiographic results for treatment with tantalum augments to reconstruct acetabular defects in primary THA.
METHODS: We retrospectively reviewed 19 patients (19 hips) with acetabular defects who underwent primary THA using tantalum augments, with a minimum follow-up of 2 years. Clinical, radiographic, and surgical data were retrospectively evaluated.
RESULTS: Mean follow-up was 5.1 years (range 2.5-7.6). Harris Hip Score improved from 35.8 (range 19-56) preoperatively to 85.3 (63-98) at last follow-up (P < .01). Oxford Hip Score, University of California Los Angeles activity scale, and Short Form-12 score also improved significantly from presurgery to last follow-up. Mean operation time and blood loss were 124.7 minutes and 530 mL, respectively. Mean hip center position was 2.97 cm (range 2.35-3.58) horizontally and 2.06 cm (1.29-2.92) vertically, and mean acetabular inclination was 38.9° (range 27°-47°) at last follow-up. These parameters were not significantly different from those recorded immediately postoperatively (P > .05). There was no aseptic loosening, cup and augment migration, screw breakage, or presence of hip infection at last follow-up. All hips were radiographically stable.
CONCLUSION: Porous tantalum augments combined with titanium shells lead to satisfactory clinical and radiographic outcomes for the reconstruction of acetabular defect in primary THA at a mean 5.1 years of follow-up. This approach confers anatomical cup placement, simple operation, and a high rate of stable fixation.
Copyright © 2017. Published by Elsevier Inc.

Entities:  

Keywords:  acetabular defect; primary; reconstruction; tantalum augments; total hip arthroplasty

Mesh:

Substances:

Year:  2017        PMID: 29033154     DOI: 10.1016/j.arth.2017.09.030

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Modular revision strategy with bispherical augments in severe acetabular deficiency reconstruction.

Authors:  Guo-Yuan Li; Xiao-Qi Zhang; Min Chen; Zheng-Liang Luo; Xiao-Feng Ji; Xi-Fu Shang
Journal:  Int Orthop       Date:  2021-08-27       Impact factor: 3.075

2.  Use of Customized 3D-Printed Titanium Augment With Tantalum Trabecular Cup for Large Acetabular Bone Defects in Revision Total Hip Arthroplasty: A Midterm Follow-Up Study.

Authors:  Keyu Kong; Chen Zhao; Yongyun Chang; Hua Qiao; Yi Hu; Huiwu Li; Jingwei Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-06-01

3.  [Research progress of total hip arthroplasty for patients with sequelae of suppurative hip arthritis].

Authors:  Yongzhi Qin; Zongke Zhou
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-01-15

4.  Cemented acetabular component with femoral neck autograft for acetabular reconstruction in Crowe type III dislocated hips.

Authors:  Eiji Goto; Hirotsugu Umeda; Makoto Otsubo; Tadashi Teranishi
Journal:  Bone Joint J       Date:  2021-02       Impact factor: 5.082

Review 5.  Advances in surface modification of tantalum and porous tantalum for rapid osseointegration: A thematic review.

Authors:  Xi Wang; Wentao Liu; Xinding Yu; Biyao Wang; Yan Xu; Xu Yan; Xinwen Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-09-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.