Literature DB >> 29031886

ZIF-67 derived porous Co3O4 hollow nanopolyhedron functionalized solution-gated graphene transistors for simultaneous detection of glucose and uric acid in tears.

Can Xiong1, Tengfei Zhang2, Weiyu Kong2, Zhixiang Zhang2, Hao Qu3, Wei Chen1, Yanbo Wang4, Linbao Luo2, Lei Zheng5.   

Abstract

Biomarkers in tears have attracted much attention in daily healthcare sensing and monitoring. Here, highly sensitive sensors for simultaneous detection of glucose and uric acid are successfully constructed based on solution-gated graphene transistors (SGGTs) with two separate Au gate electrodes, modified with GOx-CHIT and BSA-CHIT respectively. The sensitivity of the SGGT is dramatically improved by co-modifying the Au gate with ZIF-67 derived porous Co3O4 hollow nanopolyhedrons. The sensing mechanism for glucose sensor is attributed to the reaction of H2O2 generated by the oxidation of glucose near the gate, while the sensing mechanism for uric acid is due to the direct electro-oxidation of uric acid molecules on the gate. The optimized glucose and uric acid sensors show the detection limits both down to 100nM, far beyond the sensitivity required for non-invasive detection of glucose and uric acid in tears. The glucose and uric acid in real tear samples was quantitatively detected at 323.2 ± 16.1μM and 98.5 ± 16.3μM by using the functionalized SGGT device. Due to the low-cost, high-biocompatibility and easy-fabrication features of the ZIF-67 derived porous Co3O4 hollow nanopolyhedron, they provide excellent electrocatalytic nanomaterials for enhancing sensitivity of SGGTs for a broad range of disease-related biomarkers.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Glucose; Graphene transistors; High sensitivity; Porous Co(3)O(4) hollow nanopolyhedrons; Uric acid

Mesh:

Substances:

Year:  2017        PMID: 29031886     DOI: 10.1016/j.bios.2017.10.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  A colorimetric immunoassay for determination of Escherichia coli O157:H7 based on oxidase-like activity of cobalt-based zeolitic imidazolate framework.

Authors:  Shujuan Wang; Dongpo Xu; Chengchao Ding; Yachen Tian; Kangjie Ge; Liang Guo; Jie Li; Qingli Dong; Yong Huang; Qing Liu
Journal:  Mikrochim Acta       Date:  2020-08-21       Impact factor: 5.833

2.  Co3O4/carbon hollow nanospheres for resistive monitoring of gaseous hydrogen sulfide and for nonenzymatic amperometric sensing of dissolved hydrogen peroxide.

Authors:  Lihong Liu; Ming Yang; Hui Zhao; Yingming Xu; Xiaoli Cheng; Xianfa Zhang; Shan Gao; Haiyan Song; Lihua Huo
Journal:  Mikrochim Acta       Date:  2019-02-15       Impact factor: 5.833

3.  Synergetic PtNP@Co3O4 hollow nanopolyhedrals as peroxidase-like nanozymes for the dual-channel homogeneous biosensing of prostate-specific antigen.

Authors:  Xiyue Cao; Min Liu; Mu Zhao; Jie Li; Jianfei Xia; Tingting Zou; Zonghua Wang
Journal:  Anal Bioanal Chem       Date:  2022-01-10       Impact factor: 4.142

Review 4.  Recent Advancement in Biofluid-Based Glucose Sensors Using Invasive, Minimally Invasive, and Non-Invasive Technologies: A Review.

Authors:  Vundrala Sumedha Reddy; Bhawana Agarwal; Zhen Ye; Chuanqi Zhang; Kallol Roy; Amutha Chinnappan; Roger J Narayan; Seeram Ramakrishna; Rituparna Ghosh
Journal:  Nanomaterials (Basel)       Date:  2022-03-25       Impact factor: 5.076

Review 5.  Commercial and Scientific Solutions for Blood Glucose Monitoring-A Review.

Authors:  Yirui Xue; Angelika S Thalmayer; Samuel Zeising; Georg Fischer; Maximilian Lübke
Journal:  Sensors (Basel)       Date:  2022-01-06       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.