Accuracy, precision and inter-rater reliability of micro-CT analysis of false starts on bones. A preliminary validation study.

Guido Pelletti1, Giovanni Cecchetto1, Alessia Viero1, Paolo Fais2, Michael Weber3, Diego Miotto4, Massimo Montisci1, Guido Viel5, Chiara Giraudo4.   

Abstract

Micro computed tomography (micro-CT) has already been proposed as a useful technique for the qualitative analysis of false starts (FS) produced on human bones, although the reliability and the error rate of this technique have not been tested yet, neither for qualitative nor for quantitative assessments. The aim of the present study was to test the morphological agreement, accuracy, precision and inter-rater reliability of micro-CT analysis of FS on bones. The morphological agreement was assessed through the degree of concordance among the 3 independent blind raters in the identification of the shape of 24 FS manually produced on bones by 3 different saws (8 FS for each saw). The accuracy was calculated through the percentage of error in the automatic and manual measurement of the diameter of a reference object. The precision was calculated as CV% of multiple measurements performed by 3 independent blind raters on the reference object and one bone sample acquired 20 times. The inter-rater reliability was assessed as intraclass correlation coefficient (ICC) among measurements performed by 3 independent blind raters, assessing 24 FS produced using 3 different saws. The results demonstrated that both qualitative and quantitative analysis were reproducible and robust. Micro-CT analysis showed a 100% morphological agreement, a high level of accuracy (percentage error < 0,5%), precision (CV% < 5%) and inter-rater reliability (ICC > 0.995), when FS were analyzed by forensic pathologists and/or radiologists with adequate expertise. Obviously, further validation studies are needed, including a higher number of samples produced by a wider variety of saws and multiple operators.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  False starts; Forensic anthropology; Micro-CT; Qualitative and quantitative assessment; Validation study

Mesh:

Year:  2017        PMID: 29031107     DOI: 10.1016/j.legalmed.2017.10.003

Source DB:  PubMed          Journal:  Leg Med (Tokyo)        ISSN: 1344-6223            Impact factor:   1.376


  5 in total

1.  Homicide and concealment of the corpse. Autopsy case series and review of the literature.

Authors:  Maria De Matteis; Arianna Giorgetti; Guido Viel; Chiara Giraudo; Claudio Terranova; Amalia Lupi; Paolo Fais; Alessandra Puggioni; Giovanni Cecchetto; Massimo Montisci
Journal:  Int J Legal Med       Date:  2020-05-30       Impact factor: 2.686

2.  Analysis of false start bone lesions produced by an electrical oscillating autopsy saw.

Authors:  Caroline Bernardi; Luísa Nogueira; Véronique Alunni; Gérald Quatrehomme
Journal:  Int J Legal Med       Date:  2019-02-13       Impact factor: 2.686

Review 3.  Interpol review of shoe and tool marks 2016-2019.

Authors:  Martin Baiker-Sørensen; Koen Herlaar; Isaac Keereweer; Petra Pauw-Vugts; Richard Visser
Journal:  Forensic Sci Int       Date:  2020-04-02       Impact factor: 2.395

4.  Novel methodology for measuring intraoral wear in enamel and dental restorative materials.

Authors:  Josephine F Esquivel-Upshaw; Shu-Min Hsu; Ana C Bohórquez; Nader Abdulhameed; Gary W Scheiffele; Mijin Kim; Dan Neal; John Chai; Fan Ren
Journal:  Clin Exp Dent Res       Date:  2020-09-21

5.  Advantages of micro-CT in the case of a complex dismemberment.

Authors:  Kirsty Alsop; Danielle G Norman; Waltraud Baier; Jim Colclough; Mark A Williams
Journal:  J Forensic Sci       Date:  2022-02-04       Impact factor: 1.717

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.