Literature DB >> 29028275

Exposure reductions associated with introduction of solar lamps to kerosene lamp-using households in Busia County, Kenya.

N L Lam1, G Muhwezi2, F Isabirye2, K Harrison3,4, I Ruiz-Mercado5, E Amukoye6, T Mokaya6, M Wambua6, M N Bates7.   

Abstract

Solar lamps are a clean and potentially cost-effective alternative to polluting kerosene lamps used by millions of families in developing countries. By how much solar lamps actually reduce exposure to pollutants, however, has not been examined. Twenty households using mainly kerosene for lighting were enrolled through a secondary school in Busia County, Kenya. Personal PM2.5 and CO concentrations were measured on a school pupil and an adult in each household, before and after provision of 3 solar lamps. PM2.5 concentrations were measured in main living areas, pupils' bedrooms, and kitchens. Usage sensors measured use of kerosene and solar lighting devices. Ninety percent of baseline kerosene lamp use was displaced at 1-month follow-up, corresponding to average PM2.5 reductions of 61% and 79% in main living areas and pupils' bedrooms, respectively. Average 48-h exposure to PM2.5 fell from 210 to 104 μg/m3 (-50%) among adults, and from 132 to 35 μg/m3 (-73%) among pupils. Solar lamps displaced most kerosene lamp use in at least the short term. If sustained, this could mitigate health impacts of household air pollution in some contexts. Achieving safe levels of exposure for all family members would likely require also addressing use of solid-fuel stoves.
© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Keywords:  zzm321990PMzzm3219902.5zzm321990; Carbon monoxide; Kenya; Kerosene lamps; Personal exposure; Solar lamps

Mesh:

Substances:

Year:  2017        PMID: 29028275     DOI: 10.1111/ina.12433

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  3 in total

1.  Use, cost-effectiveness, and end user perspectives of a home solar lighting intervention in rural Uganda: a mixed methods, randomized controlled trial.

Authors:  Radhika Sundararajan; Helen D'Couto; Joseph Mugerwa; Mellon Tayebwa; Nicholas Lam; Eli Wallach; Matthew Wiens; Matthew Ponticiello; Debbi Stanistreet; Alexander C Tsai; Jose Vallarino; Joseph G Allen; Daniel Muyanja; Mark G Shrime; Edwin Nuwagira; Peggy S Lai
Journal:  Environ Res Lett       Date:  2021-12-22       Impact factor: 6.793

2.  Effect of a solar lighting intervention on fuel-based lighting use and exposure to household air pollution in rural Uganda: A randomized controlled trial.

Authors:  Eli S Wallach; Nicholas L Lam; Edwin Nuwagira; Daniel Muyanja; Mellon Tayebwa; Linda Valeri; Alexander C Tsai; Jose Vallarino; Joseph G Allen; Peggy S Lai
Journal:  Indoor Air       Date:  2022-02       Impact factor: 6.554

3.  Personal carbon monoxide exposure, respiratory symptoms, and the potentially modifying roles of sex and HIV infection in rural Uganda: a cohort study.

Authors:  Crystal M North; Piers MacNaughton; Peggy S Lai; Jose Vallarino; Samson Okello; Bernard Kakuhikire; Alexander C Tsai; Marcia C Castro; Mark J Siedner; Joseph G Allen; David C Christiani
Journal:  Environ Health       Date:  2019-08-20       Impact factor: 7.123

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.