Literature DB >> 29027683

Ultrasonographic Measurement of the Biceps Femoris Long-Head Muscle Architecture.

Sandro R Freitas1,2, João Marmeleira1, Maria João Valamatos1, Anthony Blazevich3, Pedro Mil-Homens1.   

Abstract

OBJECTIVES: Biceps femoris long-head architectural assessment using ultrasonography (US) has not been previously described in detail for both acquisition (image capture) and digitization (image measurement) processes, and the effect of the US window width is unknown. This study aimed to describe the reliability and test-retest minimum detectable difference of US-based biceps femoris architectural measurements.
METHODS: Muscle length was determined by marking the muscle-tendon junction distances. Sonograms were acquired with a 6-cm image width and cropped for a 3-cm width in 3 assessments (n = 20 adults). Intra- and inter-rater reliability rates were determined for both image (3- and 6-cm widths) acquisition and digitizing processes separated and together (within session) for the biceps femoris fascicle length, fascicle angle, and muscle thickness measurements using intraclass correlation coefficients (ICCs) and Pearson (r) correlation coefficients.
RESULTS: Muscle length was measured with high intra-rater (ICC = 0.93; r = 0.92) and inter-rater (ICC = 0.90; r = 0.90) reliability. Intra-rater (coefficient of variation, 0.2%-1.8%) and inter-rater (ICC = 0.79-0.99; r = 0.80-0.99) digitizing reliability rates were high. High intra-rater (ICC = 0.79-0.95; r = 0.79-0.95) and moderate-to-high inter-rater (ICC = 0.51-0.92; r = 0.70-0.93) session reliability rates were found for all architectural parameters for 6- and 3-cm images (intra-rater ICC = 0.77-0.93; r = 0.79-0.93; inter-rater ICC = 0.63-0.98; r = 0.90-0.98). The inter-rater session reliability rates for both image acquisition and digitizing processes were higher for 6-cm images (ICC = 0.65-0.86; r = 0.67-0.87) than 3-cm images (ICC = 0.28-0.93; r = 0.67-0.93). The minimum detectable differences for the 6-cm images were 8.4 mm, 1.5 °, and 1.6 mm for fascicle length, fascicle angle, and muscle thickness, respectively.
CONCLUSIONS: Ultrasonography can be used to reliably assess midmuscle architecture of the biceps femoris muscle when the same rater performs image acquisition and digitization.
© 2017 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  fascicle angle; fascicle length; hamstring; musculoskeletal; reliability; sports medicine/orthopedics; ultrasonography

Mesh:

Year:  2017        PMID: 29027683     DOI: 10.1002/jum.14436

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  Intra-session and inter-rater reliability of spatial frequency analysis methods in skeletal muscle.

Authors:  Scott K Crawford; Kenneth S Lee; Greg R Bashford; Bryan C Heiderscheit
Journal:  PLoS One       Date:  2020-07-10       Impact factor: 3.240

2.  Electrical stimulation to prevent recurring pressure ulcers in individuals with a spinal cord injury compared to usual care: the Spinal Cord Injury PREssure VOLTage (SCI PREVOLT) study protocol.

Authors:  Boas J Wijker; Sonja de Groot; Johanna M van Dongen; Femke van Nassau; Jacinthe J E Adriaansen; Wendy J Achterberg-Warmer; Johan R Anema; Andries T Riedstra; Maurits W van Tulder; Thomas W J Janssen
Journal:  Trials       Date:  2022-02-16       Impact factor: 2.279

3.  Obtaining Quality Extended Field-of-View Ultrasound Images of Skeletal Muscle to Measure Muscle Fascicle Length.

Authors:  Amy N Adkins; Wendy M Murray
Journal:  J Vis Exp       Date:  2020-12-14       Impact factor: 1.355

4.  Sprint versus isolated eccentric training: Comparative effects on hamstring architecture and performance in soccer players.

Authors:  Jurdan Mendiguchia; Filipe Conceição; Pascal Edouard; Marco Fonseca; Rogerio Pereira; Hernani Lopes; Jean-Benoît Morin; Pedro Jiménez-Reyes
Journal:  PLoS One       Date:  2020-02-11       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.