Literature DB >> 29024080

Randomized comparison of balloon aortic valvuloplasty performed with or without rapid cardiac pacing: The pacing versus no pacing (PNP) study.

Gianni Dall'Ara1,2, Antonio Marzocchi1, Nevio Taglieri1, Carolina Moretti1, Giulio Rodinò1, Matteo Chiarabelli1, Paolo Bottoni1, Cinzia Marrozzini1, Maria Rita Sabattini1, Maria-Letizia Bacchi-Reggiani1, Claudio Rapezzi1, Francesco Saia1.   

Abstract

OBJECTIVES: To compare the effectiveness and safety of balloon aortic valvuloplasty (BAV) performed with or without rapid ventricular pacing (RP).
BACKGROUND: BAV technique is poorly standardized.
METHODS: One hundred consecutive patients were randomly assigned 1:1 between BAV performed with or without RP. Exclusion criteria were an immediate indication for surgical or transcatheter aortic valve replacement, presentation in cardiogenic shock or pulmonary edema refractory to medical stabilization.
RESULTS: There were 51 patients in the BAV group performed with RP, 49 in the BAV group without RP (noRP). Procedural success (50% hemodynamic gradient reduction) was achieved in 37.3% and 55.1%, respectively (P = 0.16). Fewer people in the noRP group complained of poor tolerance to the procedure (16% vs 41%). The primary efficacy endpoint, a 50% reduction in the mean echocardiographic trans-aortic gradient, was met in 21/49 patients in the noRP group compared to 20/51 in the RP (42.9% vs 39.2%; P = 0.84). No significant difference between the groups was observed in the primary safety endpoint, a 30-day composite of death, myocardial infarction, stroke, acute aortic regurgitation, and BARC bleeding ≥3 (8.2% noRP vs 13.7%; P = 0.53). The noRP group required fewer bailout temporary pacemakers (P = 0.048) and had a lower incidence of moderate/severe renal function worsening (4.1% vs 17.6%; P = 0.052).
CONCLUSIONS: Rapid ventricular pacing did not influence BAV efficacy or safety and tolerance was slightly worse.
© 2017, Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic valve stenosis; aortic valvuloplasty; randomized trial; rapid ventricular pacing

Mesh:

Year:  2017        PMID: 29024080     DOI: 10.1111/joic.12452

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  2 in total

1.  Balloon aortic valvuloplasty in neonates: short- and long-term effects and predictors of successful outcome.

Authors:  Filip Tyc; Michal Galeczka; Jacek Białkowski; Katarzyna Kulig; Roland Fiszer
Journal:  Postepy Kardiol Interwencyjnej       Date:  2022-08-19       Impact factor: 1.065

2.  Direct Rapid Left Ventricular Wire Pacing during Balloon Aortic Valvuloplasty.

Authors:  Pawel Kleczynski; Artur Dziewierz; Sylwia Socha; Tomasz Rakowski; Marzena Daniec; Barbara Zawislak; Saleh Arif; Joanna Wojtasik-Bakalarz; Dariusz Dudek; Lukasz Rzeszutko
Journal:  J Clin Med       Date:  2020-04-03       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.