Literature DB >> 29022243

Pyrosequencing analysis of source water switch and sulfate-induced bacterial community transformation in simulated drinking water distribution pipes.

Fan Yang1, Baoyou Shi2, Weiyu Zhang1, Jing Cui3, Jianbo Guo4, Dongsheng Wang5, Nan Wu1, Xinyuan Liu1.   

Abstract

Inter-basin water transfer and source water switching will be increasingly launched due to significant population increase and the shortage of the local water resources in cities around the world. Source water switch may cause physiochemical and microbiological de-stabilization of pipe material, biofilms, and loose deposits in drinking water distribution system (DWDS). Great sulfate alteration during source water switch had been deemed as the main cause of a red water case that occurred in a northern China city. To ascertain the relationship between water quality changing and bacterial communities of biofilms in DWDS and possible bacteria risk in a red water case, water quality changing experiments in simulated DWDSs were conducted for approximately 2 years. Twenty-five corrosion scale samples and eight water samples collected from pipe harvest sites or during experimental periods were analyzed for their bacterial community composition by 454-pyrosequencing technology. Taxonomy results together with redundancy analysis (RDA) or canonical correspondence analysis (CCA) and hierarchical cluster analysis all indicated that bacterial community of samples with groundwater (GW) or surface water (SW) supply history and their variations under high sulfate water were rather different owing to different water source histories and the original pipe scale characteristics. Potential opportunistic pathogens: Burkholderia, Escherichia-Shigella, Mycobacterium, Serratia, Ralstonia, Novosphingobium, Flavobacterium, Sphingomonas, and Sphingopyxis were observed in scale or water samples.

Entities:  

Keywords:  454-pyrosequencing; Bacterial community; Disinfection-resistant bacteria; Drinking water distribution system; High-sulfate source water switch; Opportunistic pathogen; Water quality

Mesh:

Substances:

Year:  2017        PMID: 29022243     DOI: 10.1007/s11356-017-0370-y

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  25 in total

1.  Bacteria from drinking water supply and their fate in gastrointestinal tracts of germ-free mice: a phylogenetic comparison study.

Authors:  J Lee; C S Lee; K M Hugunin; C J Maute; R C Dysko
Journal:  Water Res       Date:  2010-07-21       Impact factor: 11.236

2.  Core-satellite populations and seasonality of water meter biofilms in a metropolitan drinking water distribution system.

Authors:  Fangqiong Ling; Chiachi Hwang; Mark W LeChevallier; Gary L Andersen; Wen-Tso Liu
Journal:  ISME J       Date:  2015-08-07       Impact factor: 10.302

Review 3.  Potential impacts of changing supply-water quality on drinking water distribution: A review.

Authors:  Gang Liu; Ya Zhang; Willem-Jan Knibbe; Cuijie Feng; Wentso Liu; Gertjan Medema; Walter van der Meer
Journal:  Water Res       Date:  2017-03-19       Impact factor: 11.236

4.  Airborne bacteria associated with corrosion of mild steel 1010 and aluminum alloy 1100.

Authors:  Aruliah Rajasekar; Wang Xiao; Manivannan Sethuraman; Punniyakotti Parthipan; Punniyakotti Elumalai
Journal:  Environ Sci Pollut Res Int       Date:  2017-01-31       Impact factor: 4.223

5.  Flint Water Crisis Caused By Interrupted Corrosion Control: Investigating "Ground Zero" Home.

Authors:  Kelsey J Pieper; Min Tang; Marc A Edwards
Journal:  Environ Sci Technol       Date:  2017-02-01       Impact factor: 9.028

6.  [Case study of red water phenomenon in drinking water distribution systems caused by water source switch].

Authors:  Yang Wang; Xiao-jian Zhang; Chao Chen; An-jun Pan; Yang Xu; Ping-an Liao; Su-xia Zhang; Jun-nong Gu
Journal:  Huan Jing Ke Xue       Date:  2009-12

7.  Effects of sulfate on heavy metal release from iron corrosion scales in drinking water distribution system.

Authors:  Huifang Sun; Baoyou Shi; Fan Yang; Dongsheng Wang
Journal:  Water Res       Date:  2017-02-13       Impact factor: 11.236

8.  Using Amplicon Sequencing To Characterize and Monitor Bacterial Diversity in Drinking Water Distribution Systems.

Authors:  Jennifer L A Shaw; Paul Monis; Laura S Weyrich; Emma Sawade; Mary Drikas; Alan J Cooper
Journal:  Appl Environ Microbiol       Date:  2015-07-10       Impact factor: 4.792

9.  Microbial community dynamics of an urban drinking water distribution system subjected to phases of chloramination and chlorination treatments.

Authors:  Chiachi Hwang; Fangqiong Ling; Gary L Andersen; Mark W LeChevallier; Wen-Tso Liu
Journal:  Appl Environ Microbiol       Date:  2012-08-31       Impact factor: 4.792

10.  Accumulation of arsenic in drinking water distribution systems.

Authors:  Darren A Lytle; Thomas J Sorg; Christy Frietch
Journal:  Environ Sci Technol       Date:  2004-10-15       Impact factor: 9.028

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.