Ana Carla Leite Romero1,2, Ana Cláudia Mirândola Barbosa Reis1, Anna Caroline Silva de Oliveira2, Humberto de Oliveira Simões3, Cinthia Amorim de Oliveira Junqueira4, Ana Cláudia Figueiredo Frizzo2.
Abstract
Introduction The P300 test requires well-defined and unique criteria, in addition to training for the examiners, for a uniform analysis of studies and to avoid variations and errors in the interpretation of measurement results. Objectives The objective of this study is to verify whether there are differences in P300 with and without subtraction of traces of standard and nonstandard stimuli. Method We conducted this study in collaboration with two research electrophysiology laboratories. From Laboratory 1, we selected 40 tests of subjects between 7-44 years, from Laboratory 2, we selected 83 tests of subjects between 18-44 years. We first performed the identification with the nonstandard stimuli; then, we subtracted the nonstandard stimuli from the standard stimuli. The examiners identified the waves, performing a descriptive and comparative analysis of traces with and without subtraction. Results After a comparative analysis of the traces with and without subtraction, there was no significant difference when compared with analysis of traces in both laboratories, within the conditions, of right ears ( p = 0.13 and 0.28 for differences between latency and amplitude measurements) and left ears ( p = 0.15 and 0.09 for differences between latency and amplitude measurements) from Laboratory 1. As for Laboratory 2, when investigating both ears, results did not identify significant differences ( p = 0.098 and 0.28 for differences between latency and amplitude measurements). Conclusion There was no difference verified in traces with and without subtraction. We suggest the identification of this potential performed through nonstandard stimuli.Entities:
Keywords: P300; auditory; electrophysiology; event-related potentials; evoked potentials; methods
Year: 2017 PMID: 29018497 PMCID: PMC5629085 DOI: 10.1055/s-0037-1599096
Source DB: PubMed Journal: Int Arch Otorhinolaryngol ISSN: 1809-4864
Descriptive statistics and p-values: t test of P300 latency and amplitude of measures with and without subtraction
| Group | Ear | Analysis | Variable | Mean | SD | Min | 1st Quartile | 3rd Quartile | Max |
|
|---|---|---|---|---|---|---|---|---|---|---|
| Laboratory 1 | R | with sub | lat_P300 | 335.82 | 32.35 | 275 | 308 | 352.50 | 246 | 0.136 |
| lat_P300 | 339.78 | 35.40 | 246 | 319 | 356 | 415 | ||||
| without sub | amp_P300 | 6.25 | 2.77 | 2 | 4 | 8 | 2 | 0.286 | ||
| amp_P300 | 6.59 | 2.69 | 13 | 4 | 8 | 14 | ||||
| L | with sub | lat_P300 | 327.17 | 35.29 | 274 | 301.5 | 346.50 | 411 | 0.158 | |
| amp_P300 | 330.44 | 41.92 | 246 | 304 | 355.75 | 416 | ||||
| without sub | lat_P300 | 5.69 | 3.01 | -- | 4 | 7 | 12 | 0.095 | ||
| amp_P300 | 5.81 | 3.12 | -- | 4 | 8 | 15 | ||||
| Laboratory 2 | BIN | with sub | lat_P300 | 289.90 | 34.02 | 225 | 264 | 315 | 371 | 0.095 |
| amp_P300 | 296.89 | 34.33 | 237 | 271 | 325 | 409 | ||||
| without sub | lat_P300 | 7.15 | 4.10 | -- | 4 | 9.50 | 21 | 0.280 | ||
| amp_P300 | 7.46 | 3.82 | 1 | 5 | 10 | 22 |
Abbreviations: R, right; L, left; BIN, bineural; amp, amplitude (µV); SD, standard deviation; lat, latency (ms); sub, subtraction.
Fig. 1Box plot of latency measurements: comparison with subtraction and without subtraction. Abbreviations: Bin, Binaural; LE, Left ear; RE, Right ear; WOS, without subtraction; WS, with subtraction.
Fig. 2Box plot of amplitude measurements: comparison with subtraction and without subtraction. Abbreviations: Bin, Binaural; LE, Left ear; RE, Right ear; WOS, without subtraction; WS, with subtraction.