Literature DB >> 29016734

The impact of Cone Beam CT on financial costs and orthodontists' treatment decisions in the management of maxillary canines with eruption disturbance.

Helena Christell1, Stephen Birch2,3, Lars Bondemark1, Keith Horner4, Christina Lindh1.   

Abstract

Background: Examination with Cone Beam CT (CBCT) is common for localizing maxillary canines with eruption disturbance. The benefits and costs of these examinations are unclear.
Objectives: To measure: 1. the proportion of orthodontists' treatment decisions that were different based on intraoral and panoramic radiography (M1) compared with CBCT and panoramic radiography (M2); and 2. the costs of producing different treatment plans, regarding patients with maxillary canines with eruption disturbance. Subjects and methods: Orthodontists participated in a web-based survey and were randomly assigned to denote treatment decisions and the level of confidence in this decision for four patient cases presented with M1 or M2 at two occasions for the same patient case.
Results: One hundred and twelve orthodontists made 445 assessments based on M1 and M2, respectively. Twenty-four per cent of the treatment decisions were different depending on which method the raters had access to, whereof one case differed significantly from all other cases. The mean total cost per examination was €99.84 using M1 and €134.37 using M2, resulting in an incremental cost per examination of €34.53 for M2. Limitations: Benefits in terms of number of different treatment decisions must be considered as an intermediate outcome for the effectiveness of a diagnostic method and should be interpreted with caution. Conclusions: For the patient cases presented in this study, most treatment decisions were the same irrespective of radiological method. Accordingly, this study does not support routine use of CBCT regarding patients with maxillary canine with eruption disturbance.
© The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

Entities:  

Mesh:

Year:  2018        PMID: 29016734     DOI: 10.1093/ejo/cjx039

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  3 in total

1.  Radiation dose from X-ray examinations of impacted canines: cone beam CT vs two-dimensional imaging.

Authors:  Nils Kadesjö; Randi Lynds; Mats Nilsson; Xie-Qi Shi
Journal:  Dentomaxillofac Radiol       Date:  2018-01-16       Impact factor: 2.419

Review 2.  Two-Dimensional Analysis of Digital Images through Vector Graphic Editors in Dentistry: New Calibration and Analysis Protocol Based on a Scoping Review.

Authors:  Samuel Rodríguez-López; Matías Ferrán Escobedo Martínez; Luis Junquera; María García-Pola
Journal:  Int J Environ Res Public Health       Date:  2021-04-23       Impact factor: 3.390

3.  Comparisons of the Computed Tomographic Scan and Panoramic Radiography Before Mandibular Third Molar Extraction Surgery.

Authors:  Qian Luo; Wanglun Diao; Lan Luo; Yong Zhang
Journal:  Med Sci Monit       Date:  2018-05-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.