Literature DB >> 29016384

Lumen Apposing Metal Stents (LAMSs) for Drainage of Pancreatic and Gallbladder Collections: A Meta-analysis.

Dennis Han1, Sumant Inamdar, Calvin W Lee, Larry S Miller, Arvind J Trindade, Divyesh V Sejpal.   

Abstract

BACKGROUND AND AIMS: Endoscopic ultrasound-guided transmural drainage using lumen apposing metal stents (LAMSs) is becoming a popular and promising therapeutic approach for drainage of intra-abdominal fluid collections. There has been an increasing number of studies evaluating LAMS for drainage of pancreatic pseudocysts (PP), walled-off pancreatic necrosis (WOPN), and gallbladder (GB) drainage. The aim of this meta-analysis is to analyze the literature to date regarding the clinical success, technical success, and adverse events of LAMS in treatment of pancreatic fluid collections and GB drainage.
METHODS: A comprehensive search of multiple literature databases through November 2016 was performed. Human studies with at least 10 subjects that examined the clinical success, technical success, and adverse events of LAMS in treating PP, WOPN, and GB drainage were included.
RESULTS: A total of 993 patients (608-WOPN; 204-PP; 181-GB drainage) underwent drainage from 20 trials. For drainage of WOPN, the pooled technical success was 98.9% [95% confidence interval (CI): 98.2% to 99.7%] and clinical success was 90% (95% CI: 87% to 93%) (τ=0.001). For drainage of PP, the pooled technical success was 97% (95% CI: 95% to 99%) and clinical success was 98% (95% CI: 96% to 100%), (τ=0.001). For GB drainage, the pooled technical success was 95% (95% CI: 91% to 99%) and clinical success was 93% (95% CI: 90% to 97%), (τ=0.001). Total adverse events occurred in 11% of patients with higher complication rates observed in GB drainage. There was no evidence of publication bias in this meta-analysis.
CONCLUSIONS: Endoscopic ultrasound-guided transmural drainage using LAMS is becoming a widely accepted therapeutic approach for the treatment of PP, WOPN, and GB drainage with high clinical and technical success rates and acceptable adverse events. Further prospective randomized trials reporting long-term clinical efficacy and cost-effectiveness are needed to validate LAMS as a therapeutic modality for pancreatic and GB collections.

Entities:  

Mesh:

Year:  2018        PMID: 29016384     DOI: 10.1097/MCG.0000000000000934

Source DB:  PubMed          Journal:  J Clin Gastroenterol        ISSN: 0192-0790            Impact factor:   3.062


  10 in total

1.  The safety and efficacy of a new 20-mm lumen apposing metal stent (lams) for the endoscopic treatment of pancreatic and peripancreatic fluid collections: a large international, multicenter study.

Authors:  Andrea Anderloni; Carlo Fabbri; Jose Nieto; Will Uwe; Markus Dollhopf; José Ramón Aparicio; Manuel Perez-Miranda; Ilaria Tarantino; Alexander Arlt; Frank Vleggaar; Geoffrey Vanbiervliet; Jochen Hampe; Michel Kahaleh; Juan J Vila; Barham K Abu Dayyeh; Andrew C Storm; Alessandro Fugazza; Cecilia Binda; Antoine Charachon; Sergio Sevilla-Ribota; Amy Tyberg; Moran Robert; Sachin Wani; Alessandro Repici; Amrita Sethi; Mouen A Khashab; Rastislav Kunda
Journal:  Surg Endosc       Date:  2020-04-22       Impact factor: 4.584

Review 2.  Endoscopic Ultrasound-Guided Gallbladder Drainage.

Authors:  Zain A Sobani; Christina Ling; Tarun Rustagi
Journal:  Dig Dis Sci       Date:  2020-08-04       Impact factor: 3.199

Review 3.  Candidemia after endoscopic therapy with lumen-apposing metal stent for pancreatic walled-off necrosis.

Authors:  Tajana Pavic; Davor Hrabar; Dominik Kralj; Ivan Lerotic; Doris Ogresta
Journal:  Clin J Gastroenterol       Date:  2018-01-30

4.  Cost effectiveness of endoscopic gallbladder drainage to treat acute cholecystitis in poor surgical candidates.

Authors:  Juan E Corral; Ananya Das; Paul T Krӧner; Victoria Gomez; Michael B Wallace
Journal:  Surg Endosc       Date:  2019-07-26       Impact factor: 4.584

Review 5.  Lumen Apposition: A Changing Landscape in Therapeutic Endoscopy.

Authors:  Thomas R McCarty; Christopher C Thompson
Journal:  Dig Dis Sci       Date:  2022-04-16       Impact factor: 3.199

Review 6.  What's new in the hot gallbladder: the evolving radiologic diagnosis and management of acute cholecystitis.

Authors:  James P Nugent; Jessica Li; Emily Pang; Alison Harris
Journal:  Abdom Radiol (NY)       Date:  2022-03-01

Review 7.  Alternative uses of lumen apposing metal stents.

Authors:  Prabin Sharma; Thomas R McCarty; Ankit Chhoda; Antonio Costantino; Caroline Loeser; Thiruvengadam Muniraj; Marvin Ryou; Christopher C Thompson
Journal:  World J Gastroenterol       Date:  2020-06-07       Impact factor: 5.742

Review 8.  Current uses and outcomes of lumen-apposing metal stents.

Authors:  Alessandro Mussetto; Alessandro Fugazza; Lorenzo Fuccio; Omero Triossi; Alessandro Repici; Andrea Anderloni
Journal:  Ann Gastroenterol       Date:  2018-06-26

9.  Adverse events with lumen-apposing metal stents in endoscopic gallbladder drainage: A systematic review and meta-analysis.

Authors:  Babu P Mohan; Ravishankar Asokkumar; Mohammed Shakhatreh; Rajat Garg; Suresh Ponnada; Udayakumar Navaneethan; Douglas G Adler
Journal:  Endosc Ultrasound       Date:  2019 Jul-Aug       Impact factor: 5.628

Review 10.  Futuristic Developments and Applications in Endoluminal Stenting.

Authors:  Joel Ferreira-Silva; Renato Medas; Mohit Girotra; Monique Barakat; James H Tabibian; Eduardo Rodrigues-Pinto
Journal:  Gastroenterol Res Pract       Date:  2022-01-11       Impact factor: 2.260

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.