Javad Razjouyan1, Hyoki Lee1, Sairam Parthasarathy2, Jane Mohler3, Amir Sharafkhaneh4, Bijan Najafi1. 1. Interdisciplinary Consortium on Advanced Motion Performance (iCAMP), Department of Surgery, Baylor College of Medicine, Houston, Texas. 2. UAHS Center for Sleep and Circadian Science, University of Arizona, Tucson, Arizona. 3. Arizona Center on Aging, College of Medicine, University of Arizona, Tucson, Arizona. 4. Sleep Center, Michael E. DeBakey, Veterans Affairs Medical Center, Houston, Texas.
Abstract
STUDY OBJECTIVES: To improve sleep quality assessment using a single chest-worn sensor by extracting body acceleration and sleep position changes. METHODS: Sleep patterns of 21 participants (50.8 ± 12.8 years, 47.8% female) with self-reported sleep problems were simultaneously recorded using a chest sensor (Chest), an Actiwatch (Wrist), and polysomnography (PSG) during overnight sleep laboratory assessment. An algorithm for Chest was developed to detect sleep/wake epochs based on body acceleration and sleep position/postural changes data, which were then used to estimate sleep parameters of interest. Comparisons between Chest and Wrist with respect to PSG were performed. Identification of sleep/wake epochs was assessed by estimating sensitivity, specificity, and accuracy. Agreement between sensor-derived sleep parameters and PSG was assessed using correlation coefficients and Bland-Altman analysis. RESULTS: Chest identified sleep/wake epochs with an accuracy of on average 6% higher than Wrist (85.8% versus 79.8%). Similar trends were observed for sensitivity/specificity values. Correlation between Wrist and PSG was poor for most of the sleep parameters of interest (r = 0.0-0.3); however, Chest and PSG correlation showed moderate to strong agreement (r = 0.4-0.8) with relatively low bias and high precision bias (precision): 9.2 (13.2) minutes for sleep onset latency; 17.3(34.8) minutes for total sleep time; 7.5 (29.8) minutes for wake after sleep onset; and 2.0 (7.3)% for sleep efficacy. CONCLUSIONS: Combination of sleep postural/position changes and body acceleration improved detection of sleep/wake epochs compared to wrist acceleration alone. The chest sensors also improved estimation of sleep parameters of interest with stronger agreement with PSG. Our findings may expand the application of wearable sensors to clinically assess sleep outside of a sleep laboratory.
STUDY OBJECTIVES: To improve sleep quality assessment using a single chest-worn sensor by extracting body acceleration and sleep position changes. METHODS: Sleep patterns of 21 participants (50.8 ± 12.8 years, 47.8% female) with self-reported sleep problems were simultaneously recorded using a chest sensor (Chest), an Actiwatch (Wrist), and polysomnography (PSG) during overnight sleep laboratory assessment. An algorithm for Chest was developed to detect sleep/wake epochs based on body acceleration and sleep position/postural changes data, which were then used to estimate sleep parameters of interest. Comparisons between Chest and Wrist with respect to PSG were performed. Identification of sleep/wake epochs was assessed by estimating sensitivity, specificity, and accuracy. Agreement between sensor-derived sleep parameters and PSG was assessed using correlation coefficients and Bland-Altman analysis. RESULTS: Chest identified sleep/wake epochs with an accuracy of on average 6% higher than Wrist (85.8% versus 79.8%). Similar trends were observed for sensitivity/specificity values. Correlation between Wrist and PSG was poor for most of the sleep parameters of interest (r = 0.0-0.3); however, Chest and PSG correlation showed moderate to strong agreement (r = 0.4-0.8) with relatively low bias and high precision bias (precision): 9.2 (13.2) minutes for sleep onset latency; 17.3(34.8) minutes for total sleep time; 7.5 (29.8) minutes for wake after sleep onset; and 2.0 (7.3)% for sleep efficacy. CONCLUSIONS: Combination of sleep postural/position changes and body acceleration improved detection of sleep/wake epochs compared to wrist acceleration alone. The chest sensors also improved estimation of sleep parameters of interest with stronger agreement with PSG. Our findings may expand the application of wearable sensors to clinically assess sleep outside of a sleep laboratory.
Authors: Luciane de Souza; Ana Amélia Benedito-Silva; Maria Laura Nogueira Pires; Dalva Poyares; Sergio Tufik; Helena Maria Calil Journal: Sleep Date: 2003-02-01 Impact factor: 5.849
Authors: Miriam E Nelson; W Jack Rejeski; Steven N Blair; Pamela W Duncan; James O Judge; Abby C King; Carol A Macera; Carmen Castaneda-Sceppa Journal: Circulation Date: 2007-08-01 Impact factor: 29.690
Authors: Melanie Zinkhan; Klaus Berger; Sabrina Hense; Maren Nagel; Anne Obst; Beate Koch; Thomas Penzel; Ingo Fietze; Wolfgang Ahrens; Peter Young; Svenja Happe; Jan W Kantelhardt; Alexander Kluttig; Andrea Schmidt-Pokrzywniak; Frank Pillmann; Andreas Stang Journal: Sleep Med Date: 2014-05-28 Impact factor: 3.492
Authors: Clete A Kushida; Michael R Littner; Timothy Morgenthaler; Cathy A Alessi; Dennis Bailey; Jack Coleman; Leah Friedman; Max Hirshkowitz; Sheldon Kapen; Milton Kramer; Teofilo Lee-Chiong; Daniel L Loube; Judith Owens; Jeffrey P Pancer; Merrill Wise Journal: Sleep Date: 2005-04 Impact factor: 5.849
Authors: Sarah Berryhill; Christopher J Morton; Adam Dean; Adam Berryhill; Natalie Provencio-Dean; Salma I Patel; Lauren Estep; Daniel Combs; Saif Mashaqi; Lynn B Gerald; Jerry A Krishnan; Sairam Parthasarathy Journal: J Clin Sleep Med Date: 2020-02-11 Impact factor: 4.062