Abstract

A quality-made dental impression is a prerequisite for successful fixed-prosthodontic fabrication and is directly dependent on the dimensional stability, accuracy and flexibility of the elastomeric impression materials, as well as on the appropriately used impression techniques. The purpose of this paper is to provide a literature review of relevant scientific papers which discuss the use of various silicone impression materials, different impression techniques and to evaluate their impact on the dimensional stability and accuracy of the obtained impressions. Scientific papers and studies were selected according to the materials used, the sample size, impression technique, storage time, type of measurements and use of spacer for the period between 2002 and 2016. In the reviewed literature several factors that influence the dimensional stability and accuracy of silicone impression molds, including the choice of the type of viscosity, impression material thickness, impression technique, retention of the impression material on the tray, storage time before the casting, number of castings, hydrophilicity of the material, release of byproducts, contraction after polymerization, thermal contraction and incomplete elastic recovery were presented. The literature review confirmed the lack of standardization of methodologies applied in the research and their great diversity. All findings point to the superiority of the addition silicone compared to the condensation silicone.

Entities:  

Keywords:  dimensional stability; fixed partial dentures; impression technique; review; silicone impression material

Mesh:

Substances:

Year:  2017        PMID: 28991761     DOI: 10.1515/prilozi-2017-0031

Source DB:  PubMed          Journal:  Pril (Makedon Akad Nauk Umet Odd Med Nauki)        ISSN: 1857-9345


  4 in total

1.  Evaluation of radiodensity and dimensional stability of polymeric materials used for oral stents during external beam radiotherapy of head and neck carcinomas.

Authors:  Katarina Jonovic; Mutlu Özcan; Nadin Al-Haj Husain; Kiren Jan Mätzener; Ilja Frank Ciernik
Journal:  Clin Transl Radiat Oncol       Date:  2022-06-18

2.  Effect of Core Materials on the Dimensional Accuracy of Casts Made of Two Different Silicone Impression Materials: An Experimental Study.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Mohammad-Hassan Kalantari
Journal:  J Int Soc Prev Community Dent       Date:  2020-03-05

3.  Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials-An In Vitro Study.

Authors:  Eugen S Bud; Vlad I Bocanet; Mircea H Muntean; Alexandru Vlasa; Mariana Păcurar; Irina Nicoleta Zetu; Bianca I Soporan; Anamaria Bud
Journal:  Polymers (Basel)       Date:  2022-09-05       Impact factor: 4.967

4.  An In-Vitro Evaluation of Articulation Accuracy for Digitally Milled Models vs. Conventional Gypsum Casts.

Authors:  Jason D Lee; German O Gallucci; Sang J Lee
Journal:  Dent J (Basel)       Date:  2022-01-11