Literature DB >> 28990450

Revisiting the role of durable polymers in cardiovascular devices.

Hiroyoshi Mori1, Fumiyuki Otsuka1, Anuj Gupta2, Hiroyuki Jinnouchi1, Sho Torii1, Emanuel Harari1, Renu Virmani1, Aloke V Finn1,2.   

Abstract

INTRODUCTION: Polymers are an essential component of drug-eluting stents (DES) used to control drug release but remain the most controversial component of DES technology. There are two types of polymers employed in DES: durable polymer based DES (DP-DES) and biodegradable polymer DES (BP-DES). First-generation DES were exclusively composed of DP and demonstrated increased rates of late stent failure due in part to poor polymer biocompatibility. Newer generations DES use more biocompatible durable polymers or biodegradable polymers. Areas covered: We will cover issues identified with 1st-generation DP-DES, areas of success and failure in 2nd-generation DP-DES and examine the promise and shortcomings of BP-DES. Briefly, fluorinated polymers used in 2nd-generation DP-DES have excellent anti-thrombogenicity and better biocompatibility than 1st-generation DES polymers. However, these devices lead to persistent drug exposure to the endothelium which impairs endothelial function and predisposes towards neoatherosclerosis. Meanwhile, BP-DES has shortened the duration of drug exposure which might be beneficial for endothelial functional recovery leading to less neoatherosclerosis. However, it remains uncertain whether the long-term biocompatibility of bare metal surfaces is better than that of polymer-coated metals. Expert commentary: Each technology has distinct advantages, which can be optimized depending upon the particular characteristics of the patient being treated.

Entities:  

Keywords:  Drug-eluting stent; biodegradable polymer; durable polymer; metal; neoatherosclerosis; polymer

Mesh:

Substances:

Year:  2017        PMID: 28990450     DOI: 10.1080/14779072.2017.1386098

Source DB:  PubMed          Journal:  Expert Rev Cardiovasc Ther        ISSN: 1477-9072


  4 in total

1.  Safety and Efficacy of Contemporary Drug-Eluting Stents in Patients With ST-Segment Elevation Myocardial Infarction and a High Ischemic Risk.

Authors:  Oh-Hyun Lee; Yongcheol Kim; Nak-Hoon Son; Deok-Kyu Cho; Jung-Sun Kim; Byeong-Keuk Kim; Donghoon Choi; Myeong-Ki Hong; Myung Ho Jeong; Yangsoo Jang
Journal:  Front Cardiovasc Med       Date:  2022-05-23

Review 2.  Drug-Eluting Stents and Balloons-Materials, Structure Designs, and Coating Techniques: A Review.

Authors:  I Rykowska; I Nowak; R Nowak
Journal:  Molecules       Date:  2020-10-11       Impact factor: 4.411

Review 3.  Vascular Wall Reactions to Coronary Stents-Clinical Implications for Stent Failure.

Authors:  Tommaso Gori
Journal:  Life (Basel)       Date:  2021-01-17

4.  Five-Year Comparative Efficacy of Everolimus-Eluting vs. Resolute Zotarolimus-Eluting Stents in Patients with Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention.

Authors:  Endrin Koni; Wojciech Wanha; Jakub Ratajczak; Zhongheng Zhang; Przemysław Podhajski; Rita L. Musci; Giuseppe M. Sangiorgi; Maciej Kaźmierski; Antonio Buffon; Jacek Kubica; Wojciech Wojakowski; Eliano P. Navarese
Journal:  J Clin Med       Date:  2021-03-19       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.