| Literature DB >> 28987355 |
Wang-Kyun Ryu1, Hee-Woong Kim1, Geun-Dong Kim1, Hae-Ik Rhee1,2.
Abstract
Capsaicinoids, the pungent component of chili peppers, are generally analyzed by precise analytical techniques, such as gas chromatography and high-performance liquid chromatography (HPLC), but these are not practical for the mass analyses of samples. To analyze mass samples rapidly, a colorimetric method was suggested. In this work, pigments and capsaicinoids were efficiently separated from chili pepper extract by sequential solid-liquid extraction and liquid-liquid extraction in test tubes followed by a colorimetric analysis on the capsaicinoids by a selective chromogenic reaction with Gibbs reagent (2,6-dichloroquinone-4-chloroimide). In the comparison of the capsaicinoid content by the colorimetric method and HPLC using acetone extracts of fresh pepper and dry red pepper as samples, R2 was 0.9973 and 0.9816, respectively, which shows a high linear correlation. In addition, a minimum of 1 μg/mL capsaicinoids can be detected and it was therefore determined that the method can efficiently analyze a great quantity of samples in a short time.Entities:
Keywords: capsaicinoids; colorimetric method; liquid–liquid extraction; solid–liquid extraction
Mesh:
Substances:
Year: 2016 PMID: 28987355 PMCID: PMC9328869 DOI: 10.1016/j.jfda.2016.11.007
Source DB: PubMed Journal: J Food Drug Anal Impact factor: 6.157
Figure 1The calibration curve of capsaicin partitioned from n-hexane to 0.05N NaOH solution.
Figure 2Thin-layer chromatogram of pepper extracts. Lane 1, acetone extract of fresh pepper; Lane 2, n-hexane extract from dried Lane 1; Lane 3, upper layer (partitioning between Lane 2 and 0.05N NaOH); Lane 4, lower layer (partitioning between Lane 2 and 0.05N NaOH); Lane 5, acetone extract of dried red pepper; Lane 6, n-hexane extract from dried Lane 5; Lane 7, upper layer (partitioning between Lane 6 and 0.05N NaOH); Lane 8, lower layer (partitioning between Lane 6 and 0.05N NaOH). Thin-layer chromatography plate was developed with a solvent system of toluene/chloroform/acetone (55/26/19, v/v/v). Then, 0.1% 2,6-dichloroquinone-4-chloroimide solution was sprayed and color was developed in an ammonia vapor chamber.
Comparison of the capsaicinoids content according to quantification methods from fresh pepper.
| Sample | Capsaicinoids (μg/g) | (Colorimetric/HPLC) × 100 (%) | |
|---|---|---|---|
|
| |||
| HPLC | Colorimetric | ||
| FP 1 | 144.9 | 134.7 | 93.0 |
| FP 2 | 232.7 | 221.8 | 95.3 |
| FP 3 | 235.3 | 219.7 | 93.4 |
| FP 4 | 426.1 | 419.0 | 98.4 |
| FP 5 | 557.7 | 551.2 | 98.8 |
| FP 6 | 315.8 | 284.4 | 90.1 |
| FP 7 | 278.1 | 264.6 | 95.1 |
| FP 8 | 236.5 | 228.5 | 96.6 |
| FP 9 | 392.8 | 358.6 | 91.3 |
| FP 10 | 94.3 | 90.5 | 96.0 |
| FP 11 | 22.4 | 22.1 | 98.7 |
| FP 12 | 108.1 | 106.0 | 98.0 |
| FP 13 | 145.7 | 142.5 | 97.8 |
| FP 14 | 13.4 | 12.7 | 95.0 |
| FP 15 | 104.0 | 103.8 | 99.8 |
| FP 16 | 336.1 | 323.9 | 96.4 |
| FP 17 | 218.5 | 215.2 | 98.5 |
| FP 18 | 40.6 | 39.5 | 97.3 |
| FP 19 | 266.6 | 247.8 | 92.9 |
| FP 20 | 463.1 | 432.9 | 93.5 |
| FP 21 | 288.2 | 267.2 | 92.7 |
| FP 22 | 69.6 | 67.5 | 97.0 |
| FP 23 | 462.9 | 450.2 | 97.3 |
| FP 24 | 84.0 | 80.7 | 96.1 |
| FP 25 | 183.9 | 174.5 | 94.9 |
| FP 26 | 411.1 | 382.7 | 93.1 |
| FP 27 | 113.9 | 103.8 | 91.1 |
| FP 28 | 45.3 | 44.1 | 97.4 |
| FP 29 | 105.2 | 104.5 | 99.4 |
| FP 30 | 147.4 | 139.6 | 94.7 |
| Average ± deviation | 95.8 ± 2.5 | ||
FP = fresh pepper; HPLC = high-performance liquid chromatography.
Comparison of the capsaicinoids content according to quantification methods from dry red pepper.
| Sample | Capsaicinoids (μg/g) | (Colorimetric/HPLC) × 100 (%) | |
|---|---|---|---|
|
| |||
| HPLC | Colorimetric | ||
| DP 1 | 859.0 | 901.2 | 104.9 |
| DP 2 | 855.2 | 921.1 | 107.7 |
| DP 3 | 988.4 | 988.0 | 96.9 |
| DP 4 | 622.6 | 676.8 | 108.7 |
| DP 5 | 1186.4 | 1122.0 | 94.6 |
| DP 6 | 558.8 | 580.3 | 103.8 |
| DP 7 | 645.6 | 659.8 | 102.2 |
| DP 8 | 174.0 | 164.2 | 94.3 |
| DP 9 | 889.2 | 882.7 | 99.3 |
| DP 10 | 715.2 | 749.3 | 104.8 |
| DP 11 | 798.2 | 861.4 | 107.9 |
| Average ± deviation | 102.3 ± 5.2 | ||
DP = dry red pepper; HPLC = high-performance liquid chromatography.
Figure 3A correlation between the colorimetric method and high-performance liquid chromatography (HPLC) in quantification of capsaicinoids from (A) fresh pepper and (B) dry red pepper.