Literature DB >> 28987018

Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obese Colombian adults.

Robinson Ramírez-Vélez1, Alejandra Tordecilla-Sanders1, Jorge Enrique Correa-Bautista1, Katherine González-Ruíz2, Emilio González-Jiménez3,4, Hector Reynaldo Triana-Reina5, Antonio García-Hermoso6, Jacqueline Schmidt-RioValle3,4.   

Abstract

OBJECTIVES: To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method.
METHODS: Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland-Altman difference plots.
RESULTS: Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P = .001). The paired t-test showed a significant mean difference between these methods for obese men BF% of -0.6 [(SD 1.95; 95% CI = -4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was -0.6 [(SD 2.2; 95% CI = -5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978).
CONCLUSIONS: Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations.
© 2017 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2017        PMID: 28987018     DOI: 10.1002/ajhb.23071

Source DB:  PubMed          Journal:  Am J Hum Biol        ISSN: 1042-0533            Impact factor:   1.937


  2 in total

1.  Effects of age and gender on body composition indices as predictors of mortality in middle-aged and old people.

Authors:  Chin-Sung Chang; I-Ting Liu; Fu-Wen Liang; Chia-Chun Li; Zih-Jie Sun; Yin-Fan Chang; Ting-Hsing Chao; Chih-Hsing Wu
Journal:  Sci Rep       Date:  2022-05-12       Impact factor: 4.996

2.  Excess serum uric acid is associated with metabolic syndrome in obese adolescent patients.

Authors:  Christy Foster; Loretta Smith; Ramin Alemzadeh
Journal:  J Diabetes Metab Disord       Date:  2020-05-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.