Literature DB >> 28985894

In vivo fascicle length measurements via B-mode ultrasound imaging with single vs dual transducer arrangements.

Scott F Brennan1, Andrew G Cresswell2, Dominic J Farris2, Glen A Lichtwark2.   

Abstract

Ultrasonography is a useful technique to study muscle contractions in vivo, however larger muscles like vastus lateralis may be difficult to visualise with smaller, commonly used transducers. Fascicle length is often estimated using linear trigonometry to extrapolate fascicle length to regions where the fascicle is not visible. However, this approach has not been compared to measurements made with a larger field of view for dynamic muscle contractions. Here we compared two different single-transducer extrapolation methods to measure VL muscle fascicle length to a direct measurement made using two synchronised, in-series transducers. The first method used pennation angle and muscle thickness to extrapolate fascicle length outside the image (extrapolate method). The second method determined fascicle length based on the extrapolated intercept between a fascicle and the aponeurosis (intercept method). Nine participants performed maximal effort, isometric, knee extension contractions on a dynamometer at 10° increments from 50 to 100° of knee flexion. Fascicle length and torque were simultaneously recorded for offline analysis. The dual transducer method showed similar patterns of fascicle length change (overall mean coefficient of multiple correlation was 0.76 and 0.71 compared to extrapolate and intercept methods respectively), but reached different absolute lengths during the contractions. This had the effect of producing force-length curves of the same shape, but each curve was shifted in terms of absolute length. We concluded that dual transducers are beneficial for studies that examine absolute fascicle lengths, whereas either of the single transducer methods may produce similar results for normalised length changes, and repeated measures experimental designs.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Fascicle; Length; Muscle; Tracking; Ultrasound

Mesh:

Year:  2017        PMID: 28985894     DOI: 10.1016/j.jbiomech.2017.09.019

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Surface properties affect the interplay between fascicles and tendinous tissues during landing.

Authors:  Enzo Hollville; Antoine Nordez; Gaël Guilhem; Jennyfer Lecompte; Giuseppe Rabita
Journal:  Eur J Appl Physiol       Date:  2019-11-27       Impact factor: 3.078

2.  Circulating Tumor Necrosis Factor Alpha May Modulate the Short-Term Detraining Induced Muscle Mass Loss Following Prolonged Resistance Training.

Authors:  Gerard McMahon; Christopher I Morse; Keith Winwood; Adrian Burden; Gladys L Onambélé
Journal:  Front Physiol       Date:  2019-05-03       Impact factor: 4.566

3.  The effects of knee extensor moment biofeedback on gait biomechanics and quadriceps contractile behavior.

Authors:  Amanda E Munsch; Brian Pietrosimone; Jason R Franz
Journal:  PeerJ       Date:  2020-07-08       Impact factor: 2.984

4.  Mechanical work accounts for most of the energetic cost in human running.

Authors:  R C Riddick; A D Kuo
Journal:  Sci Rep       Date:  2022-01-12       Impact factor: 4.996

5.  Age-related declines in muscle and respiratory function are proportionate to declines in performance in Master Track Cyclists.

Authors:  Pablo Duro Ocana; Mohammad Z Darabseh; Kengo Ishihara; Aseel Aburub; Fabio Zambolin; Gallin Montgomery; Richard Mills; Matteo Scorcelletti; James Cameron; Bergita Ganse; Hans Degens; Liam Bagley
Journal:  Eur J Appl Physiol       Date:  2021-09-13       Impact factor: 3.078

6.  Altered countermovement jump force profile and muscle-tendon unit kinematics following combined ballistic training.

Authors:  Ben W Hoffman; Brent J Raiteri; Mark J Connick; Emma M Beckman; Angelo Macaro; Vincent G Kelly; Lachlan P James
Journal:  Scand J Med Sci Sports       Date:  2022-07-27       Impact factor: 4.645

7.  Effect of the Knee and Hip Angles on Knee Extensor Torque: Neural, Architectural, and Mechanical Considerations.

Authors:  Yoann M Garnier; Romuald Lepers; Patrizio Canepa; Alain Martin; Christos Paizis
Journal:  Front Physiol       Date:  2022-01-04       Impact factor: 4.566

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.