Literature DB >> 28985446

Preparation Ferrule Design Effect on Endocrown Failure Resistance.

Michael Einhorn1, Nicholas DuVall2, Michael Wajdowicz3, John Brewster3, Howard Roberts3.   

Abstract

PURPOSE: To evaluate the effect of preparation ferrule inclusion with fracture resistance of mandibular molar endocrowns.
MATERIALS AND METHODS: Recently extracted mandibular third molars were randomly divided into 3 groups (n = 12) with the coronal tooth structure removed perpendicular to the root long axis approximately 2 mm above the cemento-enamel junction with a slow-speed diamond saw. The pulp chamber was exposed using a diamond bur in a high-speed handpiece with pulpal remnants removed and canals instrumented using endodontic hand instruments. The chamber floor was restored using a resin core material with a two-step, self-etch adhesive and photopolymerized with a visible light-curing unit to create a 2 mm endocrown preparation pulp chamber extension. One and two millimeter ferrule height groups were prepared using a diamond bur in a high-speed handpiece following CAD/CAM guidelines. Completed preparation surface area was determined using a digital measuring microscope. Scanned preparations were restored with lithium disilicate restorations with a self-adhesive resin luting agent. All manufacturer recommendations were followed. Specimens were stored at 37°C/98% humidity and tested to failure after 24 hours at a 45° angle to the tooth long axis using a universal testing machine. Failure load was converted to MPa using the available bonding surface area with mean data analyzed using Kruskal-Wallis/Dunn (p = 0.05).
RESULTS: Calculated failure stress found no difference in failure resistance among the three groups; however, failure load results identified that the endocrown preparations without ferrule had significantly lower fracture load resistance. Failure mode analysis identified that all preparations demonstrated a high number of catastrophic failures.
CONCLUSIONS: Under the conditions of this study, ferrule-containing endocrown preparations demonstrated significantly greater failure loads than standard endocrown restorations; however, calculated failure stress based on available surface area for adhesive bonding found no difference between the groups. Lower instances of catastrophic failure were observed with the endocrown preparations containing 1 mm of preparation ferrule design; however, regardless of the presence of ferrule, this study found that all endocrown restorations suffered a high proportion of catastrophic failures but at loads greater than reported under normal masticatory function.
© 2017 by the American College of Prosthodontists.

Entities:  

Keywords:  CAD/CAM; endodontically treated teeth; failure load; failure stress; lithium disilicate; preparation features

Mesh:

Substances:

Year:  2017        PMID: 28985446     DOI: 10.1111/jopr.12671

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  7 in total

1.  Flow Cytometry Analysis of Antibacterial Effects of Universal Dentin Bonding Agents on Streptococcus mutans.

Authors:  Barbara Lapinska; Magdalena Konieczka; Beata Zarzycka; Krzysztof Sokolowski; Janina Grzegorczyk; Monika Lukomska-Szymanska
Journal:  Molecules       Date:  2019-02-01       Impact factor: 4.411

2.  The impact of restorative material and ceramic thickness on CAD\CAM endocrowns.

Authors:  João-Paulo-Mendes Tribst; Amanda-Maria-de Oliveira Dal Piva; Camila-Ferreira-Leite Madruga; Marcia-Carneiro Valera; Eduardo Bresciani; Marco-Antonio Bottino; Renata-Marques de Melo
Journal:  J Clin Exp Dent       Date:  2019-11-01

3.  Influence of margin design and restorative material on the stress distribution of endocrowns: a 3D finite element analysis.

Authors:  Ziting Zheng; Jieli Sun; Lifang Jiang; Yuan Wu; Jiahui He; Wenhao Ruan; Wenjuan Yan
Journal:  BMC Oral Health       Date:  2022-02-05       Impact factor: 2.757

4.  Endocrown restorations for extensively damaged posterior teeth: clinical performance of three cases.

Authors:  Konstantinos Tzimas; Maria Tsiafitsa; Paris Gerasimou; Effrosyni Tsitrou
Journal:  Restor Dent Endod       Date:  2018-08-22

5.  Fracture resistance, failure mode and stress concentration in a modified endocrown design.

Authors:  Wiam El Ghoul; Mutlu Özcan; Joao Paulo Mendes Tribst; Ziad Salameh
Journal:  Biomater Investig Dent       Date:  2020-08-07

6.  Post-Fatigue Fracture and Marginal Behavior of Endodontically Treated Teeth: Partial Crown vs. Full Crown vs. Endocrown vs. Fiber-Reinforced Resin Composite.

Authors:  Roland Frankenberger; Julia Winter; Marie-Christine Dudek; Michael Naumann; Stefanie Amend; Andreas Braun; Norbert Krämer; Matthias J Roggendorf
Journal:  Materials (Basel)       Date:  2021-12-15       Impact factor: 3.623

7.  Biomechanical behavior of endocrowns vs fiber post-core-crown vs cast post-core-crown for the restoration of maxillary central incisors with 1 mm and 2 mm ferrule height: A 3D static linear finite element analysis.

Authors:  Xixi Li; Ting Kang; Danting Zhan; Jing Xie; Ling Guo
Journal:  Medicine (Baltimore)       Date:  2020-10-23       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.