Literature DB >> 28980129

Rupture of the aortic root : A rare but life-threatening complication of transcatheter aortic valve replacement.

Christian Reiter1, Michael Grund2, Alexander Nahler2, Clemens Steinwender2,3, Thomas Lambert2.   

Abstract

Transcatheter aortic valve replacement (TAVR) has been shown to be a valid treatment option for patients with significant symptomatic aortic valve stenosis and high surgical risk. Rupture of the aortic root is a rare but life-threatening complication that occurs in approximately 1% of procedures and usually manifests as an acute complication at the time of valve implantation; however, physicians should be aware of a potentially subacute onset, since early recognition and immediate management are crucial. While many potential causes have been described, it is currently unknown which combinations will lead to its occurrence. Accurate preprocedural assessment of the aortic annulus and its adjacent structures as well as adequate sizing of the prosthetic valve are important steps to prevent rupture of the device landing zone.

Entities:  

Keywords:  Aortic root rupture; Aortic valve stenosis; Complication; Heart valve diseases; Transcatheter aortic valve replacement

Mesh:

Year:  2017        PMID: 28980129     DOI: 10.1007/s00508-017-1272-1

Source DB:  PubMed          Journal:  Wien Klin Wochenschr        ISSN: 0043-5325            Impact factor:   1.704


  10 in total

Review 1.  Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications.

Authors:  Jean-Bernard Masson; Jan Kovac; Gerhard Schuler; Jian Ye; Anson Cheung; Samir Kapadia; Murat E Tuzcu; Susheel Kodali; Martin B Leon; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

2.  Aortic and right ventricular rupture in a patient after transcatheter aortic valve implantation; The direction of the calcification predicts aortic annulus rupture.

Authors:  Atila Iyisoy; Cengiz Ozturk; Sait Demirkol; Turgay Celik; Mustafa Aparci; Mustafa Demir; Ali Osman Yildirim; Mehmet Ali Sahin
Journal:  Int J Cardiol       Date:  2015-05-12       Impact factor: 4.164

Review 3.  Standard imaging techniques in transcatheter aortic valve replacement.

Authors:  Arash Salemi; Berhane M Worku
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

Review 4.  Emergent cardiac surgery during transcatheter aortic valve implantation (TAVI): a weighted meta-analysis of 9,251 patients from 46 studies.

Authors:  Holger Eggebrecht; Axel Schmermund; Philipp Kahlert; Raimund Erbel; Thomas Voigtländer; Rajendra H Mehta
Journal:  EuroIntervention       Date:  2013-01-22       Impact factor: 6.534

5.  Contained rupture of the aortic annulus after transcatheter aortic valve implantation: uncommon presentation of a rare complication.

Authors:  Valérie Rodgers; François Gobeil; Nicolas Noiseux; Louis-Mathieu Stevens; Lyne Bérubé; Yves Provost; Jean-Bernard Masson
Journal:  Can J Cardiol       Date:  2014-01-24       Impact factor: 5.223

6.  Perioperative Results and Complications in 15,964 Transcatheter Aortic Valve Replacements: Prospective Data From the GARY Registry.

Authors:  Thomas Walther; Christian W Hamm; Gerhard Schuler; Alexander Berkowitsch; Joachim Kötting; Norman Mangner; Harald Mudra; Andreas Beckmann; Jochen Cremer; Armin Welz; Rüdiger Lange; Karl-Heinz Kuck; Friedrich W Mohr; Helge Möllmann
Journal:  J Am Coll Cardiol       Date:  2015-03-15       Impact factor: 24.094

7.  Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.

Authors:  Marco Barbanti; Tae-Hyun Yang; Josep Rodès Cabau; Corrado Tamburino; David A Wood; Hasan Jilaihawi; Phillip Blanke; Raj R Makkar; Azeem Latib; Antonio Colombo; Giuseppe Tarantini; Rekha Raju; Ronald K Binder; Giang Nguyen; Melanie Freeman; Henrique B Ribeiro; Samir Kapadia; James Min; Gudrun Feuchtner; Ronen Gurtvich; Faisal Alqoofi; Marc Pelletier; Gian Paolo Ussia; Massimo Napodano; Fabio Sandoli de Brito; Susheel Kodali; Bjarne L Norgaard; Nicolaj C Hansson; Gregor Pache; Sergio J Canovas; Hongbin Zhang; Martin B Leon; John G Webb; Jonathon Leipsic
Journal:  Circulation       Date:  2013-06-07       Impact factor: 29.690

Review 8.  Annular rupture during transcatheter aortic valve replacement: classification, pathophysiology, diagnostics, treatment approaches, and prevention.

Authors:  Miralem Pasic; Axel Unbehaun; Semih Buz; Thorsten Drews; Roland Hetzer
Journal:  JACC Cardiovasc Interv       Date:  2015-01       Impact factor: 11.195

9.  Emergency cardiac surgery during transfemoral and transapical transcatheter aortic valve implantation: incidence, reasons, management, and outcome of 411 patients from a single center.

Authors:  Daniel P Griese; Wilko Reents; Sebastian Kerber; Anno Diegeler; Jörg Babin-Ebell
Journal:  Catheter Cardiovasc Interv       Date:  2013-07-19       Impact factor: 2.692

10.  Rupture of the device landing zone during transcatheter aortic valve implantation: a life-threatening but treatable complication.

Authors:  Miralem Pasic; Axel Unbehaun; Stephan Dreysse; Semih Buz; Thorsten Drews; Marian Kukucka; Giuseppe D'Ancona; Burkhardt Seifert; Roland Hetzer
Journal:  Circ Cardiovasc Interv       Date:  2012-05-15       Impact factor: 6.546

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.