Literature DB >> 28978282

Acute Swine Model for Assessing Biocompatibility of Biomedical Interface Materials.

Tohru Takaseya1, Hideyuki Fumoto1, Junmin Zhu2, Akira Shiose1, Mariko Kobayashi1, Masako Fujiki1, Yoko Arakawa1, Raymond Dessoffy1, Larry D Kramer1, Kiyotaka Fukamachi1.   

Abstract

We established an acute animal model for early, straightforward, and reproducible assessment of a biocompatible material interface. Bilateral femoral artery-to-vein shunts were created in 12 pigs: two tubes per shunt, the left two coated and the right two uncoated. We evaluated two groups: uncontrolled flow (UF; shunt flow unregulated) and controlled flow (CF; shunt flow ∼50 mL/min). For each case on each side, two shunts were evaluated: one for 1 h and the other for 3 h. Arterial blood gas and complete blood count were recorded at baseline, 1, and 3 h. Mean shunt flows were 532 ± 88 mL/min UF and 52 ± 8 mL/min CF. Differences in flow were much smaller in CF (0.5 mL/min; 1% of mean flow) than UF (24.8 mL/min; 5% of mean flow). In UF, significant changes occurred: in pH, from start of shunting through 1 h; in pO2 and pCO2, from start through 3 h. This swine model using bilateral femoral shunts with controlled blood flow provides a reliable, reproducible, easily implemented method by which to evaluate biocompatibility of device coatings at an early stage of investigation.

Entities:  

Keywords:  arteriovenous shunt; biocompatible materials; blood coagulation; device coating; swine model

Mesh:

Substances:

Year:  2017        PMID: 28978282      PMCID: PMC5816348          DOI: 10.1089/ten.TEC.2017.0310

Source DB:  PubMed          Journal:  Tissue Eng Part C Methods        ISSN: 1937-3384            Impact factor:   3.056


  12 in total

1.  Characteristics of titanium-coated polyester prostheses in the animal model.

Authors:  Torsten Ueberrueck; Lutz Meyer; Roland Zippel; Ingo Gastinger
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2005-01-15       Impact factor: 3.368

2.  Post-explant visualization of thrombi in outflow grafts and their junction to a continuous-flow total artificial heart using a high-definition miniaturized camera.

Authors:  Jamshid H Karimov; David Horvath; Gengo Sunagawa; Nicole Byram; Nader Moazami; Leonard A R Golding; Kiyotaka Fukamachi
Journal:  J Artif Organs       Date:  2015-05-05       Impact factor: 1.731

3.  Human endothelial cell interaction with biomimetic surfactant polymers containing Peptide ligands from the heparin binding domain of fibronectin.

Authors:  Sharon Sagnella; Eric Anderson; Naomi Sanabria; Roger E Marchant; Kandice Kottke-Marchant
Journal:  Tissue Eng       Date:  2005 Jan-Feb

Review 4.  The influence of thrombus components in mediating bacterial adhesion to biomaterials.

Authors:  N M Lamba; J N Baumgartner; S L Cooper
Journal:  J Biomater Sci Polym Ed       Date:  2000       Impact factor: 3.517

5.  Platelet and endothelial adhesion on fluorosurfactant polymers designed for vascular graft modification.

Authors:  Chad Tang; Faina Kligman; Coby C Larsen; Kandice Kottke-Marchant; Roger E Marchant
Journal:  J Biomed Mater Res A       Date:  2009-02       Impact factor: 4.396

6.  In vitro and in vivo study of sustained nitric oxide release coating using diazeniumdiolate-oped poly(vinyl chloride) matrix with poly(lactide-co-glycolide) additive.

Authors:  Hitesh Handa; Elizabeth J Brisbois; Terry C Major; Lahdan Refahiyat; Kagya A Amoako; Gail M Annich; Robert H Bartlett; Mark E Meyerhoff
Journal:  J Mater Chem B       Date:  2013-08-07       Impact factor: 6.331

7.  Glycocalyx-mimetic dextran-modified poly(vinyl amine) surfactant coating reduces platelet adhesion on medical-grade polycarbonate surface.

Authors:  A Sen Gupta; S Wang; E Link; E H Anderson; C Hofmann; J Lewandowski; K Kottke-Marchant; R E Marchant
Journal:  Biomaterials       Date:  2006-02-03       Impact factor: 12.479

8.  Design and synthesis of biomimetic hydrogel scaffolds with controlled organization of cyclic RGD peptides.

Authors:  Junmin Zhu; Chad Tang; Kandice Kottke-Marchant; Roger E Marchant
Journal:  Bioconjug Chem       Date:  2009-02       Impact factor: 4.774

9.  Thrombogenicity of flow diverters in an ex vivo shunt model: effect of phosphorylcholine surface modification.

Authors:  Matthew W Hagen; Gaurav Girdhar; John Wainwright; Monica T Hinds
Journal:  J Neurointerv Surg       Date:  2016-10-31       Impact factor: 5.836

Review 10.  Biomaterials in cardiovascular research: applications and clinical implications.

Authors:  Saravana Kumar Jaganathan; Eko Supriyanto; Selvakumar Murugesan; Arunpandian Balaji; Manjeesh Kumar Asokan
Journal:  Biomed Res Int       Date:  2014-05-08       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.