Literature DB >> 28976599

Biomechanical investigation of two long bone growth modulation techniques by finite element simulations.

Manuel Schneider1, Jan Buschbaum1, Alexander Joeris2, Oliver Röhrle3, Jonathan Dwyer4, James B Hunter5, Richard A K Reynolds6, Theodor F Slongo7, Boyko Gueorguiev1, Peter Varga1.   

Abstract

Implants used to correct pathological varus-valgus deformities (VVD) and leg length discrepancies (LLD) may not be optimized for the specific treatment, as suggested by their off-label use. Detailed analysis of this issue has been limited by the poorly understood mechanical behavior of the growing physis and ignorance of the loads acting on the implants. The aim of this study was to predict and compare the loading conditions of a growth modulation implant in VVD and LLD treatments. Idealized finite element (FE) models of the juvenile distal femur treated with the Eight-Plate implant were developed for VVD and LLD. Bone growth was simulated using thermal strains. The axial force in the plate was compared between the two treatments. Case-specific plate forces were predicted by virtually reproducing the screw deformation visible on radiographs of LLD (N = 4) and VVD (N = 4) clinical cases. The simple FE models reproduced the clinical implant deformations well. The resulting forces ranged from 129 to 580 N for the VVD patients. For LLD, this range was from 295 to 1002 N per plate, that is, 590-2004 N for the entire physis. The higher forces in LLD could be explained by restricted screw divergence in the double-sided implant application. For the first time, the loading conditions of a growth modulation implant were investigated and compared between two treatments by FE analyses, and the range of case-specific loads was predicted. These simulation tools may be utilized for guiding appropriate usage and for efficient development of implants.
© 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1398-1405, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  Eight-Plate; bone growth modulation; finite element analysis; leg length discrepancy; varus-valgus deformity

Mesh:

Year:  2017        PMID: 28976599     DOI: 10.1002/jor.23762

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  1 in total

1.  Growth modulation of angular deformities with a novel constant force implant concept-preclinical results.

Authors:  Jan Buschbaum; Linda Freitag; Theodor F Slongo; Stephan Zeiter; Michael Schütz; Markus Windolf
Journal:  J Child Orthop       Date:  2021-04-19       Impact factor: 1.548

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.