Literature DB >> 28972801

Adequacy of percutaneous non-targeted liver biopsy under real-time ultrasound guidance when comparing the Biopince™ and Achieve™ biopsy needle.

Thomas C Hall1, Claire Deakin2, Gurprit Ss Atwal2, Rajeev K Singh1.   

Abstract

OBJECTIVE: The purpose of this study was to compare the adequacy rates of percutaneous liver biopsies, in parenchymal liver disease, using the BiopinceTM (Argon Medical, Texas, TX, ) 16G and AchieveTM (Carefusion, Illinois, IL, USA) 18G biopsy needles in relation to the Royal College of Pathologists guidelines and to assess risk of complications.
METHODS: Data for all percutaneous non-targeted "medical" liver biopsies using the Biopince 16G and Achieve 18G biopsy needles were collected retrospectively over a 2-year period. Total biopsy core length and number of portal tracts was recorded along with adequacy of biopsy as assessed according to Royal College of Pathologists criteria.
RESULTS: In total, 194 percutaneous liver biopsies met the inclusion criteria; 53 using the Biopince needle and 141 using the Achieve needle. The mean total core length was 23 mm (SD 4.1) and 20 mm (SD 6.8) for the Biopince and Achieve needles, respectively (p = 0.0005). The mean number of portal tracts was 11 (SD 4.2) and 7 (SD 3.4) for the Biopince and Achieve needles, respectively (p < 0.0001). An adequate biopsy was obtained in 15 (31.3%) and 1 (1.3%) case using the Biopince and Achieve needles, respectively (p < 0.001). Compromised biopsies were obtained in 32 (66.7%) and 39 (50.6%) cases using the Biopince and Achieve needles, respectively. Inadequate biopsies were obtained in 1 (2%) and 37 (48.1%) cases using the Biopince and Achieve needles, respectively.
CONCLUSION: The Biopince 16G needle, when compared with the Achieve 18G needle, acquires a significantly greater total core length and number of portal tracts with significantly improved adequacy rates. There were no major complications associated with its use. Advances in knowledge: The Biopince 16G needle achieves significantly better specimen adequacy, when compared with the Achieve 18G needle and with no added major complications associated with its use.

Entities:  

Mesh:

Year:  2017        PMID: 28972801      PMCID: PMC6047660          DOI: 10.1259/bjr.20170397

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  17 in total

Review 1.  Liver biopsy sampling in chronic viral hepatitis.

Authors:  Maria Guido; Massimo Rugge
Journal:  Semin Liver Dis       Date:  2004-02       Impact factor: 6.115

Review 2.  A systematic review of the quality of liver biopsy specimens.

Authors:  Evangelos Cholongitas; Marco Senzolo; Richard Standish; Laura Marelli; Alberto Quaglia; David Patch; Amar P Dhillon; Andrew Kenneth Burroughs
Journal:  Am J Clin Pathol       Date:  2006-05       Impact factor: 2.493

3.  Liver biopsy.

Authors:  Don C Rockey; Stephen H Caldwell; Zachary D Goodman; Rendon C Nelson; Alastair D Smith
Journal:  Hepatology       Date:  2009-03       Impact factor: 17.425

4.  Percutaneous US-guided renal biopsy: a retrospective study comparing the 16-gauge end-cut and 14-gauge side-notch needles.

Authors:  Andre Constantin; Marie-Laure Brisson; Janet Kwan; Francesca Proulx
Journal:  J Vasc Interv Radiol       Date:  2010-02-04       Impact factor: 3.464

5.  Findings of the UK national audit evaluating image-guided or image-assisted liver biopsy. Part I. Procedural aspects, diagnostic adequacy, and accuracy.

Authors:  David C Howlett; Karl J Drinkwater; David Lawrence; Susan Barter; Tony Nicholson
Journal:  Radiology       Date:  2012-12       Impact factor: 11.105

6.  Reduced mortality rates following elective percutaneous liver biopsies.

Authors:  Joe West; Timothy R Card
Journal:  Gastroenterology       Date:  2010-06-12       Impact factor: 22.682

7.  Findings of the UK national audit evaluating image-guided or image-assisted liver biopsy. Part II. Minor and major complications and procedure-related mortality.

Authors:  David C Howlett; Karl J Drinkwater; David Lawrence; Susan Barter; Tony Nicholson
Journal:  Radiology       Date:  2012-11-09       Impact factor: 11.105

8.  HCV-related fibrosis progression following liver transplantation: increase in recent years.

Authors:  M Berenguer; L Ferrell; J Watson; M Prieto; M Kim; M Rayón; J Córdoba; A Herola; N Ascher; J Mir; J Berenguer; T L Wright
Journal:  J Hepatol       Date:  2000-04       Impact factor: 25.083

9.  Importance of specimen size in accurate needle liver biopsy evaluation of patients with chronic hepatitis C.

Authors:  Thomas D Schiano; Samia Azeem; Carol A Bodian; Henry C Bodenheimer; Sukma Merati; Swan N Thung; Prodromos Hytiroglou
Journal:  Clin Gastroenterol Hepatol       Date:  2005-09       Impact factor: 11.382

10.  Impact of liver biopsy size on histological evaluation of chronic viral hepatitis: the smaller the sample, the milder the disease.

Authors:  Guido Colloredo; Maria Guido; Aurelio Sonzogni; Gioacchino Leandro
Journal:  J Hepatol       Date:  2003-08       Impact factor: 25.083

View more
  4 in total

Review 1.  Enhancing the Value of Histopathological Assessment of Allograft Biopsy Monitoring.

Authors:  Michelle A Wood-Trageser; Andrew J Lesniak; Anthony J Demetris
Journal:  Transplantation       Date:  2019-07       Impact factor: 4.939

2.  A real-world study evaluating ultrasound-guided percutaneous non-targeted liver biopsy needle failures and pathology sample-quality assessment in both end-cut and side-notch needles.

Authors:  Jim Zhong; Rachel Allard; Dominic Hewitson; Michael Weston; Oliver Hulson; Simon Burbidge; Hannah Lambie; Tom Kaye; Judith I Wyatt; Raneem Albazaz
Journal:  Br J Radiol       Date:  2021-07-28       Impact factor: 3.629

3.  Guidelines on the use of liver biopsy in clinical practice from the British Society of Gastroenterology, the Royal College of Radiologists and the Royal College of Pathology.

Authors:  James Neuberger; Jai Patel; Helen Caldwell; Susan Davies; Vanessa Hebditch; Coral Hollywood; Stefan Hubscher; Salil Karkhanis; Will Lester; Nicholas Roslund; Rebecca West; Judith I Wyatt; Mathis Heydtmann
Journal:  Gut       Date:  2020-05-28       Impact factor: 23.059

4.  Incidence of Complications from Percutaneous Biopsy in Chronic Liver Disease: A Systematic Review and Meta-Analysis.

Authors:  Helena B Thomaides-Brears; Naim Alkhouri; Daniela Allende; Mukesh Harisinghani; Mazen Noureddin; Nancy S Reau; Marika French; Carlos Pantoja; Sofia Mouchti; Donna R H Cryer
Journal:  Dig Dis Sci       Date:  2021-06-15       Impact factor: 3.487

  4 in total