Literature DB >> 28967333

American Academy of Periodontology Best Evidence Consensus Statement on Selected Oral Applications for Cone-Beam Computed Tomography.

George A Mandelaris1,2, E Todd Scheyer3,4, Marianna Evans5,6, David Kim7, Bradley McAllister8,9, Marc L Nevins7,10, Hector F Rios11, David Sarment12,11.   

Abstract

BACKGROUND: The American Academy of Periodontology (AAP) recently embarked on a Best Evidence Consensus (BEC) model of scientific inquiry to address questions of clinical importance in periodontology for which there is insufficient evidence to arrive at a definitive conclusion. This review addresses oral indications for use of cone-beam computed tomography (CBCT).
METHODS: To develop the BEC, the AAP convened a panel of experts with knowledge of CBCT and substantial experience in applying CBCT to a broad range of clinical scenarios that involve critical structures in the oral cavity. The panel examined a clinical scenario or treatment decision that would likely benefit from additional evidence and interpretation of evidence, performed a systematic review on the individual, debated the merits of published data and experiential information, developed a consensus report, and provided a clinical bottom line based on the best evidence available.
RESULTS: This BEC addressed the potential value and limitations of CBCT relative to specific applications in the management of patients requiring or being considered for the following clinical therapies: 1) placement of dental implants; 2) interdisciplinary dentofacial therapy involving orthodontic tooth movement in the management of malocclusion with associated risk on the supporting periodontal tissues (namely, dentoalveolar bone); and 3) management of periodontitis.
CONCLUSION: For each specific question addressed, there is a critical mass of evidence, but insufficient evidence to support broad conclusions or definitive clinical practice guidelines.

Entities:  

Keywords:  Cone-beam computed tomography; consensus; dental implants; orthodontics; periodontal diseases; radiation exposure

Mesh:

Year:  2017        PMID: 28967333     DOI: 10.1902/jop.2017.170234

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  7 in total

1.  Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications.

Authors:  Vaishnavi Bhaskar; Hsun-Liang Chan; Mark MacEachern; Oliver D Kripfgans
Journal:  Dentomaxillofac Radiol       Date:  2018-06-06       Impact factor: 2.419

2.  Ultrasonographic evaluation of edentulous crestal bone topography: A proof-of-principle retrospective study.

Authors:  Khaled Sinjab; Oliver D Kripfgans; Alice Ou; Hsun-Liang Chan
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2021-07-18

3.  Comparative Evaluation of Periodontal Osseous Defects Using Direct Digital Radiography and Cone-Beam Computed Tomography.

Authors:  Ruhi Mark; Ranjana Mohan; M Gundappa; M D Saravana Balaji; V K Vijay; M Umayal
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

4.  Ultrasonography for diagnosis of peri-implant diseases and conditions: a detailed scanning protocol and case demonstration.

Authors:  Hsun-Liang Chan; Oliver D Kripfgans
Journal:  Dentomaxillofac Radiol       Date:  2020-02-06       Impact factor: 2.419

5.  Role of Computed Tomography Scan in Dental Trauma: A Cross-Sectional Study.

Authors:  Feng Li; Jun Li; Deming Zhang; Feng Wu
Journal:  Dose Response       Date:  2018-08-23       Impact factor: 2.658

6.  Digital three-dimensional visualization of intrabony periodontal defects for regenerative surgical treatment planning.

Authors:  Daniel Palkovics; Francesco Guido Mangano; Katalin Nagy; Peter Windisch
Journal:  BMC Oral Health       Date:  2020-12-01       Impact factor: 2.757

7.  Accuracy and Reliability of CBCT Compared to Clinical Probing in Detection of Trifurcation Defects: An In Vivo Study.

Authors:  Abdulaziz Mohammad Alsakr; Adriana G Creanga; Abdullah Saad Alqahtani; Khalid Gufran
Journal:  Biomed Res Int       Date:  2022-04-14       Impact factor: 3.246

  7 in total