Literature DB >> 28965017

Computational analysis of the dose rates at JSI TRIGA reactor irradiation facilities.

K Ambrožič1, G Žerovnik2, L Snoj3.   

Abstract

The JSI TRIGA Mark II, IJS research reactor is equipped with numerous irradiation positions, where samples can be irradiated by neutrons and γ-rays. Irradiation position selection is based on its properties, such as physical size and accessibility, as well as neutron and γ-ray spectra, flux and dose intensities. This paper presents an overview on the neutron and γ-ray fluxes, spectra and dose intensities calculations using Monte Carlo MCNP software and ENDF/B-VII.0 nuclear data libraries. The dose-rates are presented in terms of ambient dose equivalents, air kerma, and silicon dose equivalent. At full reactor power the neutron ambient dose equivalent ranges from 5.5×103Svh-1 to 6×106Svh-1, silicon dose equivalent from 6×102Gy/hsi to 3×105Gy/hsi, and neutron air kerma from 4.3×103Gyh-1 to 2×105Gyh-1. Ratio of fast (1MeV<E) vs. thermal neutrons (E<0.625eV) ranges from 1.5 to 8.4×10-2,γ ray ambient dose equivalent at full reactor power from 3.4×103Svh-1 to 3.6×105Svh-1 and γ air kerma range 3.1×103Gyh-1 to 2.9×105Gyh-1.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  ANSI-ANS6.1.11977; Flux to dose conversion factors; ICRP-21; ICRP-74; Irradiation positions; Neutron flux and spectrum; Research reactor; TRIGA; γ flux and spectrum

Year:  2017        PMID: 28965017     DOI: 10.1016/j.apradiso.2017.09.022

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  3 in total

1.  Use of Gaussian process regression for radiation mapping of a nuclear reactor with a mobile robot.

Authors:  Andrew West; Ioannis Tsitsimpelis; Mauro Licata; Anz E Jazbec; Luka Snoj; Malcolm J Joyce; Barry Lennox
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

2.  Experimental study of consistency degradation of different greases in mixed neutron and gamma radiation.

Authors:  Matteo Ferrari; Aldo Zenoni; Monika Hartl; Yongjoong Lee; Alberto Andrighetto; Alberto Monetti; Andrea Salvini; Fabio Zelaschi
Journal:  Heliyon       Date:  2019-09-25

3.  Sterilization of polypropylene membranes of facepiece respirators by ionizing radiation.

Authors:  Luka Pirker; Anja Pogačnik Krajnc; Jan Malec; Vladimir Radulović; Anton Gradišek; Andreja Jelen; Maja Remškar; Igor B Mekjavić; Janez Kovač; Miran Mozetič; Luka Snoj
Journal:  J Memb Sci       Date:  2020-10-01       Impact factor: 8.742

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.