Tamás Kőszegi1, Nikolett Sali2, Maja Raknić3, Zoltán Horváth-Szalai2, Rita Csepregi2, Marijana Zovko Končić4, Nóra Papp5, Miklós Poór6. 1. Department of Laboratory Medicine, University of Pécs, 7624 Pécs, Ifjúság 13, Hungary; János Szentágothai Research Center, University of Pécs, 7624 Pécs, Ifjúság 20, Hungary. Electronic address: tamas.koszegi@aok.pte.hu. 2. Department of Laboratory Medicine, University of Pécs, 7624 Pécs, Ifjúság 13, Hungary. 3. Department of Pharmacognosy, University of Zagreb, Marulicev trg. 20/II, Zagreb, Croatia. 4. Department of Pharmacognosy, University of Zagreb, Marulicev trg. 20/II, Zagreb, Croatia. Electronic address: mzovko@pharma.hr. 5. Department of Pharmacognosy, University of Pécs, 7624 Pécs, Rókus 2, Hungary. Electronic address: nora4595@gamma.ttk.pte.hu. 6. Department of Pharmacology, Faculty of Pharmacy, University of Pécs, 7624 Pécs, Szigeti 12, Hungary. Electronic address: poor.miklos@pte.hu.
Abstract
INTRODUCTION: Reactive oxygen species (ROS) are normal metabolic products of living cells. However, a decrease of the defense mechanisms against the effects of ROS or increased ROS production maybe one important causative factor of cellular damage. A non-enzymatic scavenger system is considered to be responsible for the maintenance of total antioxidant capacity (TAC) as a protection against oxidative injuries that exist in all higher plants and in mammals as well. METHODS: In our work, we optimized and validated a luminol-peroxidase-4-iodophenol-H2O2 enhanced chemiluminescence-based (ECL) TAC measurement technique. BSA was applied in the reagent to prevent peroxidase from auto-oxidation. The ECL method was suitable for plant extracts and for human blood serum as well. Our TAC technique was adapted to microplates and compared to ORAC assay using plant extracts. RESULTS AND DISCUSSION: The ECL method is fast (10min) with an interassay precision of <10% as CV. TAC values of ethanolic extracts of 10 plant species did correlate (ECL vs ORAC assay data: r=0.84, 95% confidence interval, CI=0.78-0.89, P<0.001) but with systematic bias. Analysis of serum samples obtained from septic and control patients showed significantly higher TAC values in the patient group compared to those of controls (p<0.01). Moreover, we could discriminate between surviving and non-surviving patients, based on their TAC values (p<0.01). Pearson's statistics showed the strongest positive correlation with serum uric acid (r=0.73). Besides the routine laboratory parameters, our novel TAC method might give complementary information on the severity of systemic inflammation.
INTRODUCTION:Reactive oxygen species (ROS) are normal metabolic products of living cells. However, a decrease of the defense mechanisms against the effects of ROS or increased ROS production maybe one important causative factor of cellular damage. A non-enzymatic scavenger system is considered to be responsible for the maintenance of total antioxidant capacity (TAC) as a protection against oxidative injuries that exist in all higher plants and in mammals as well. METHODS: In our work, we optimized and validated a luminol-peroxidase-4-iodophenol-H2O2 enhanced chemiluminescence-based (ECL) TAC measurement technique. BSA was applied in the reagent to prevent peroxidase from auto-oxidation. The ECL method was suitable for plant extracts and for human blood serum as well. Our TAC technique was adapted to microplates and compared to ORAC assay using plant extracts. RESULTS AND DISCUSSION: The ECL method is fast (10min) with an interassay precision of <10% as CV. TAC values of ethanolic extracts of 10 plant species did correlate (ECL vs ORAC assay data: r=0.84, 95% confidence interval, CI=0.78-0.89, P<0.001) but with systematic bias. Analysis of serum samples obtained from septic and control patients showed significantly higher TAC values in the patient group compared to those of controls (p<0.01). Moreover, we could discriminate between surviving and non-surviving patients, based on their TAC values (p<0.01). Pearson's statistics showed the strongest positive correlation with serum uric acid (r=0.73). Besides the routine laboratory parameters, our novel TAC method might give complementary information on the severity of systemic inflammation.
Authors: Balázs Németh; Iván Péter; Imre Boncz; Anna Jagicza; István Kiss; Ágnes Csergő; Tamás Kőszegi; Péter Kustán; Iván G Horváth; Zénó Ajtay Journal: Ther Clin Risk Manag Date: 2019-07-05 Impact factor: 2.423
Authors: Sourav Das; Barbara Vörös-Horváth; Tímea Bencsik; Giuseppe Micalizzi; Luigi Mondello; Györgyi Horváth; Tamás Kőszegi; Aleksandar Széchenyi Journal: Molecules Date: 2020-05-21 Impact factor: 4.411
Authors: Marianna Kocsis; Alexandra Bodó; Tamás Kőszegi; Rita Csepregi; Rita Filep; Gyula Hoffmann; Ágnes Farkas Journal: Int J Mol Sci Date: 2022-01-11 Impact factor: 5.923