Literature DB >> 28961473

Resolving the adverse impact of mobility on myoelectric pattern recognition in upper-limb multifunctional prostheses.

Oluwarotimi Williams Samuel1, Xiangxin Li2, Yanjuan Geng3, Mojisola Grace Asogbon4, Peng Fang5, Zhen Huang6, Guanglin Li7.   

Abstract

Electromyogram pattern recognition (EMG-PR) based control for upper-limb prostheses conventionally focuses on the classification of signals acquired in a controlled laboratory setting. In such a setting, relatively stable and high performances are often reported because subjects could consistently perform muscle contractions corresponding to a targeted limb motion. Meanwhile the clinical implementation of EMG-PR method is characterized by degradations in stability and classification performances due to the disparities between the constrained laboratory setting and clinical use. One of such disparities is the mobility of subject that would cause changes in the EMG signal patterns when eliciting identical limb motions in mobile scenarios. In this study, the effect of mobility on the performance of EMG-PR motion classifier was firstly investigated based on myoelectric and accelerometer signals acquired from six upper-limb amputees across four scenarios. Secondly, three methods were proposed to mitigate such effect on the EMG-PR motion classifier. From the obtained results, an average classification error (CE) of 9.50% (intra-scenario) was achieved when data from the same scenarios were used to train and test the EMG-PR classifier, while the CE increased to 18.48% (inter-scenario) when trained and tested with dataset from different scenarios. This implies that mobility would significantly lead to about 8.98% increase of classification error (p < 0.05). By applying the proposed methods, the degradation in classification performance was significantly reduced from 8.98% to 1.86% (Dual-stage sequential method), 3.17% (Hybrid strategy), and 4.64% (Multi-scenario strategy). Hence, the proposed methods may potentially improve the clinical robustness of the currently available multifunctional prostheses. TRIAL REGISTRATION: The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Amputees; EMG-Pattern recognition; Effect of mobility; Limb motion identification; Upper-limb prostheses control

Mesh:

Year:  2017        PMID: 28961473     DOI: 10.1016/j.compbiomed.2017.09.013

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  3 in total

1.  Towards Efficient Decoding of Multiple Classes of Motor Imagery Limb Movements Based on EEG Spectral and Time Domain Descriptors.

Authors:  Oluwarotimi Williams Samuel; Yanjuan Geng; Xiangxin Li; Guanglin Li
Journal:  J Med Syst       Date:  2017-10-28       Impact factor: 4.460

2.  Feature Extraction of Surface Electromyography Using Wavelet Weighted Permutation Entropy for Hand Movement Recognition.

Authors:  Xiaoyun Liu; Xugang Xi; Xian Hua; Hujiao Wang; Wei Zhang
Journal:  J Healthc Eng       Date:  2020-11-24       Impact factor: 2.682

Review 3.  Real-Time EMG Based Pattern Recognition Control for Hand Prostheses: A Review on Existing Methods, Challenges and Future Implementation.

Authors:  Nawadita Parajuli; Neethu Sreenivasan; Paolo Bifulco; Mario Cesarelli; Sergio Savino; Vincenzo Niola; Daniele Esposito; Tara J Hamilton; Ganesh R Naik; Upul Gunawardana; Gaetano D Gargiulo
Journal:  Sensors (Basel)       Date:  2019-10-22       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.