Literature DB >> 28960636

Comparison of Clinical, Radiographic, and Immunologic Inflammatory Parameters around Crestally and Subcrestally Placed Dental Implants: 5-Year Retrospective Results.

Mohammad D Al Amri1, Sara A Alfadda1, Nawaf Y Labban1, Mohammed N Alasqah2, Fahad A Alshehri3, Abdulaziz S Al-Rasheed3.   

Abstract

PURPOSE: To compare changes in clinical (bleeding on probing [BOP] and probing pocket depth [PPD]), radiographic (crestal bone loss [CBL]), and immunologic inflammatory (interleukin-1beta [IL-1β] and matrix metalloproteinase-9 [MMP-9]) parameters around crestally and subcrestally placed dental implants 5 years after implant placement.
MATERIALS AND METHODS: Fifty-two patients were divided into 2 groups: group 1 (n = 27): patients with single implants placed approximately 2 mm below the alveolar crest; group 2 (n = 25): patients with single implants placed at bone level. In both groups, peri-implant BOP, PPD, and CBL were measured, and levels of IL-1β and MMP-9 were determined in duplicates using enzyme-linked immunosorbent assay. Full-mouth debridement was performed biannually in both groups. Statistical analysis was performed using the Mann-Whitney U test (significance set at p < 0.05).
RESULTS: All measurements in groups 1 and 2 were performed 5.3 ± 0.2 and 5.2 ± 0.1 years after implant placement, respectively. The mean CBL was 1.2 ± 0.2 mm and 1.4 ± 0.2 mm in groups 1 and 2, respectively. There was no significant difference in mean BOP, PPD, CBL and in levels of IL-1β, and MMP-9 among implants in both groups.
CONCLUSION: Clinical, radiographic, and immunologic inflammatory parameters are comparable around crestally and subcrestally placed single dental implants up to 5 years after placement. The depth of implant placement appears to have no effect on clinical status and performance of single dental implants.
© 2017 by the American College of Prosthodontists.

Entities:  

Keywords:  Crestal bone loss; crestal placement; dental implants; peri-implant inflammation; proinflammatory cytokines; subcrestal

Mesh:

Substances:

Year:  2017        PMID: 28960636     DOI: 10.1111/jopr.12637

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  1 in total

1.  The effect of low-level laser 810 nm and light-emitting diode photobiomodulation (626 nm) on the stability of the implant and inflammatory markers interleukin-1 beta and prostaglandin E2, around implants.

Authors:  Jafar Memarian; Mohammad Ketabi; Shahram Amini
Journal:  Dent Res J (Isfahan)       Date:  2018 Jul-Aug
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.