Arterial catheterisation in neonates can result in severe ischaemic complications but does not impair long-term extremity function.

Philipp Deindl1,2, Thomas Waldhör3, Lukas Unterasinger2, Angelika Berger2, Maike Keck4.   

Abstract

AIM: We evaluated the incidence of arterial catheterisation and analysed the risk factors and the extent and outcome of ischaemic complications in neonates.
METHODS: This was a retrospective cohort study of 1506 neonates admitted to two, ten-bed neonatal intensive care units (NICUs) at the Medical University of Vienna, Austria, between 1 January 2011 and 31 December 2014. Medical charts, daily reports and photo documentation were reviewed for arterial catheterisation and ischaemic complications. Patients with severe ischaemic complications were followed up to evaluate extremity function, scaring and cosmetic results.
RESULTS: There were 542 arterial catheterisations in 485 patients, including 275 born below 28 weeks, which resulted in severe complications in 19 of 485 (4%) patients. Three died before follow-up. Patients with complications had a significantly lower birthweight, lower postmenstrual age and higher rates of intracranial haemorrhage, retinopathy of prematurity and necrotising enterocolitis. They had also undergone multiple arterial catheterisations more often, needed longer inotropic support and had longer NICU stays than patients without complications. Extremity function was unimpaired in ten of 16 patients with severe ischaemic complications.
CONCLUSION: Severe ischaemic complications in neonates following arterial catheterisation were rare events, but could cause devastating damage. Most patients didn't show impaired extremity function at follow-up. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Arterial catheterisation; Extremity function; Ischaemia; Neonate; Scar quality

Mesh:

Year:  2017        PMID: 28960442     DOI: 10.1111/apa.14100

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  2 in total

1.  Adverse events associated with umbilical catheters: a systematic review and meta-analysis.

Authors:  Kim Gibson; Rebecca Sharp; Amanda Ullman; Scott Morris; Tricia Kleidon; Adrian Esterman
Journal:  J Perinatol       Date:  2021-07-16       Impact factor: 2.521

2.  Discrepancy between invasive and non-invasive blood pressure readings in extremely preterm infants in the first four weeks of life.

Authors:  Tobias Werther; Lukas Aichhorn; Sigrid Baumgartner; Angelika Berger; Katrin Klebermass-Schrehof; Ulrike Salzer-Muhar
Journal:  PLoS One       Date:  2018-12-28       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.