Long-term outcomes of the current remote magnetic catheter navigation technique for ablation of atrial fibrillation.

Shiwen Yuan1, Fredrik Holmqvist1, Ole Kongstad1, Steen M Jensen1, Lingwei Wang1, Erik Ljungström1, Eva Hertervig1, Rasmus Borgquist1.   

Abstract

OBJECTIVES: Comparisons between remote magnetic (RMN) and manual catheter navigation for atrial fibrillation (AF) ablation have earlier been reported with controversial results. However, these reports were based on earlier generations of the RMN system.
DESIGN: To evaluate the outcomes of the most current RMN system for AF ablation in a larger patient population with longer follow-up time, 112 patients with AF (78 paroxysmal, 34 persistent) who underwent AF ablation utilizing RMN (RMN group) were compared to 102 AF ablation patients (72 paroxysmal, 30 persistent) utilizing manual technique (Manual group).
RESULTS: The RMN group was associated with significantly shorter fluoroscopy time (10.4 ± 6.4 vs. 16.3 ± 10.9 min, p < .001) but used more RF energy (64.1 ± 19.4KJ vs. 54.3 ± 24.1 KJ, p < .05), while total procedure time showed no significant difference (201 ± 35 vs. 196 ± 44 min, NS). After 39 ± 9/44 ± 10 months of follow-up, AF-free rates at 1year, 2 years and 3.5 years post ablation were 63%, 46% and 42% in the RMN group vs. 60%, 32% and 30% (survival analysis p < .05) in the Manual group, whereas clinically effective rates were 82%, 73% and 70% for the former vs. 70%, 56% and 49% for the latter (survival analysis p < .005).
CONCLUSION: Differing from previous reports, our data from a larger patient population and longer follow-up time demonstrates that compared to manual technique, the most current RMN technique is associated with better procedural and clinical outcomes for AF ablation.

Entities:  

Keywords:  Atrial fibrillation; ablation; long-term outcome; remote magnetic navigation

Mesh:

Year:  2017        PMID: 28958165     DOI: 10.1080/14017431.2017.1384566

Source DB:  PubMed          Journal:  Scand Cardiovasc J        ISSN: 1401-7431            Impact factor:   1.589


  4 in total

1.  Radiofrequency atrial fibrillation ablation with irrigated tip catheter using remote magnetic navigation compared with conventional manual method.

Authors:  Rugheed Ghadban; Kristina Gifft; Zachary Luebbering; Sandeep Sodhi; Daniel Cooper; Tariq Enezate
Journal:  J Interv Card Electrophysiol       Date:  2020-09-22       Impact factor: 1.900

2.  Robotics for neuroendovascular intervention: Background and primer.

Authors:  Kazim H Narsinh; Ricardo Paez; Kerstin Mueller; M Travis Caton; Amanda Baker; Randall T Higashida; Van V Halbach; Christopher F Dowd; Matthew R Amans; Steven W Hetts; Alexander M Norbash; Daniel L Cooke
Journal:  Neuroradiol J       Date:  2021-08-16

3.  Comparisons of efficacy, safety, and recurrence risk factors of paroxysmal and persistent atrial fibrillation catheter ablation using robotic magnetic navigation system.

Authors:  Xiao-Xi Zhao; Ku-Lin Li; Ru-Xing Wang; Jie Zheng; Xiao-Yu Liu; Shi-Peng Dang; Zhi-Ming Yu; Chang-Ying Zhang; Xiang-Jun Yang
Journal:  Clin Cardiol       Date:  2019-03-15       Impact factor: 2.882

Review 4.  Magnetic Particle Imaging: An Emerging Modality with Prospects in Diagnosis, Targeting and Therapy of Cancer.

Authors:  Zhi Wei Tay; Prashant Chandrasekharan; Benjamin D Fellows; Irati Rodrigo Arrizabalaga; Elaine Yu; Malini Olivo; Steven M Conolly
Journal:  Cancers (Basel)       Date:  2021-10-21       Impact factor: 6.575

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.