Literature DB >> 28953037

Comparison of Dried Blood Spots Versus Conventional Plasma Collection for the Characterization of Efavirenz Pharmacokinetics in a Large-Scale Global Clinical Trial-The ENCORE1 Study.

Alieu B Amara1, Laura J Else, Dianne Carey, Saye Khoo, David J Back, Janaki Amin, Sean Emery, Rebekah L Puls.   

Abstract

BACKGROUND: The aim of this study was to determine the utility of dried blood spots (DBS) compared with conventional plasma collection methods for characterization of efavirenz pharmacokinetics, in the setting of a large-scale, global clinical trial (ENCORE1).
METHODS: Six hundred thirty patients were recruited from 38 sites and had single matched whole blood DBS and plasma samples (mid-dose interval) taken at weeks 4 and 12 of treatment. In addition, a subgroup of patients underwent intensive DBS and plasma sampling (0-24 hours) to provide full-profile data for pharmacokinetic parameters. Efavirenz concentrations were determined by validated high-performance liquid chromatography-mass spectrometry methods. A DBS-predicted plasma concentration was derived and linear regression and Bland-Altman plots were used to compare DBS-predicted plasma concentrations with that of measured plasma concentrations.
RESULTS: Efavirenz DBS and plasma concentrations were significantly correlated (R = 0.904, P < 0.001; n = 1094), and DBS concentrations were, on average, 53% ± 9.5% lower than plasma. In the main study, the DBS-predicted plasma values significantly underestimated the true measured concentration of efavirenz in plasma; the mean difference (95% confidence interval) between efavirenz DBS-predicted concentrations and measured plasma concentrations was -0.451 mg/L (-0.504 to -0.398) at week 4 (n = 561). However, in the intensive study, the mean difference was only 0.086 mg/L (-0.006 to 0.178) at 12 hours after dose (n = 46) and was not statistically significant.
CONCLUSIONS: Our data show a high correlation between measurements of efavirenz concentrations in plasma and in DBS. However, DBS concentrations significantly underestimated the true measured plasma concentrations in the sparse samples taken in this large multinational ENCORE1 trial.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28953037     DOI: 10.1097/FTD.0000000000000448

Source DB:  PubMed          Journal:  Ther Drug Monit        ISSN: 0163-4356            Impact factor:   3.681


  5 in total

1.  Validation and clinical application of a novel LC-MS method for quantification of dolutegravir in breast milk.

Authors:  Joshua Gini; Sujan Dilly Penchala; Alieu Amara; Elizabeth Challenger; Deirdre Egan; Catriona Waitt; Mohammed Lamorde; Catherine Orrell; Landon Myer; Saye Khoo; Laura J Else
Journal:  Bioanalysis       Date:  2018-11-19       Impact factor: 2.681

Review 2.  Adherence Measurements in HIV: New Advancements in Pharmacologic Methods and Real-Time Monitoring.

Authors:  Jose R Castillo-Mancilla; Jessica E Haberer
Journal:  Curr HIV/AIDS Rep       Date:  2018-02       Impact factor: 5.071

Review 3.  Dried Blood Spots for Global Health Diagnostics and Surveillance: Opportunities and Challenges.

Authors:  Mark D Lim
Journal:  Am J Trop Med Hyg       Date:  2018-06-28       Impact factor: 2.345

4.  Validation and Clinical Application of a Liquid Chromatography-Ultraviolet Detection Method to Quantify Dolutegravir in Dried Blood Spots.

Authors:  Abdulafeez Akinloye; Oluwasegun Eniayewu; Babatunde Adeagbo; Oluseye Bolaji; Adeniyi Olagunju
Journal:  Ther Drug Monit       Date:  2022-06-01       Impact factor: 3.118

5.  Associations between efavirenz concentrations, pharmacogenetics and neurocognitive performance in people living with HIV in Nigeria.

Authors:  Jacinta N Nwogu; Monica Gandhi; Andrew Owen; Saye H Khoo; Babafemi Taiwo; Adeniyi Olagunju; Baiba Berzins; Hideaki Okochi; Regina Tallerico; Kevin Robertson; Chinedum P Babalola
Journal:  AIDS       Date:  2021-10-01       Impact factor: 4.632

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.